Grant: Research Tools and Instruments - Category 1 (<$150,000)
Université de Montréal
$30,040.00
Diffusion measurements in biofilms and the subsurface- environmental chamber for controlling temperature and atmosphere
FY 2010-11
Summary
We have requested a specialized, fully custom designed enclosure for a laser scanning microscope that is equipped to perform fluorescence correlation spectroscopy (FCS). It provides thermal stabilization, gas and humidity control for the FCS instrument. We currently use FCS for the determination of molecular dynamics in cells, solutions and nanostructures. With FCS, we are able to precisely measure diffusion coefficients on a near single molecule basis with minimal sample perturbation. The technique is much more sensitive (orders of magnitude) and rapid (several fold) than comparable techniques for determining diffusion coefficients, such as pulsed field gradient nuclear magnetic resonance (PFG-NMR) and flow field flow fractionation (FlFFF). The system requested here will be specially prepared for use with our Leica TCS SP5 laser scanning microscope. Specifically, the application is for a specialized, fully custom designed enclosure for the microscope that provides thermal stabilization in addition to gas and humidity control for the instrument. It is designed to stabilize the temperature of the entire microscope (± 0.1 oC) for temperatures ranging from 5 to 50 oC. The programmable precision air heater quickly and reliably compensates for external temperature differences. Furthermore, atmosphere can be accurately controlled by programmable inputs of air, N2, CO2 or O2. Since water evaporation from the experimental media would result in a rise in osmolarity, gases are humidified by a column mounted inside the temperature controlled microscope enclosure. A stage top incubator is used in order to restrict the humid gas to the sample area only (thus avoiding damage to the microscope electronics, optics and mechanics). To our knowledge, this would be the first FCS in Canada that would be equipped with the temperature, gas and humidity control.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
407927-2011
Name nom
Wilkinson, Kevin
Department département
Chimie
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2011
Award amount
30040
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1506
Committee name en
Geosciences
Committee name fr
Géosciences
Area of application code
1002
Area of application group en
Northern development
Area of application group fr
Développement du nord
Area of application en
Environment
Area of application fr
Environnement
Research subject code
3500
Research subject group en
Analytical chemistry
Research subject group fr
Chimie analytique
Research subject en
Analytical chemistry
Research subject fr
Chimie analytique
Partie
1
Nb partie
1
Application title
Diffusion measurements in biofilms and the subsurface- environmental chamber for controlling temperature and atmosphere
Keyword
NSERC
Application summary
We have requested a specialized, fully custom designed enclosure for a laser scanning microscope that is equipped to perform fluorescence correlation spectroscopy (FCS). It provides thermal stabilization, gas and humidity control for the FCS instrument. We currently use FCS for the determination of molecular dynamics in cells, solutions and nanostructures. With FCS, we are able to precisely measure diffusion coefficients on a near single molecule basis with minimal sample perturbation. The technique is much more sensitive (orders of magnitude) and rapid (several fold) than comparable techniques for determining diffusion coefficients, such as pulsed field gradient nuclear magnetic resonance (PFG-NMR) and flow field flow fractionation (FlFFF). The system requested here will be specially prepared for use with our Leica TCS SP5 laser scanning microscope. Specifically, the application is for a specialized, fully custom designed enclosure for the microscope that provides thermal stabilization in addition to gas and humidity control for the instrument. It is designed to stabilize the temperature of the entire microscope (± 0.1 oC) for temperatures ranging from 5 to 50 oC. The programmable precision air heater quickly and reliably compensates for external temperature differences. Furthermore, atmosphere can be accurately controlled by programmable inputs of air, N2, CO2 or O2. Since water evaporation from the experimental media would result in a rise in osmolarity, gases are humidified by a column mounted inside the temperature controlled microscope enclosure. A stage top incubator is used in order to restrict the humid gas to the sample area only (thus avoiding damage to the microscope electronics, optics and mechanics). To our knowledge, this would be the first FCS in Canada that would be equipped with the temperature, gas and humidity control.