Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Alliance Grants

University of British Columbia

$29,573.00

Assessment of ultraviolet disinfection for unfiltered water supplies

FY 2021-22

Summary
Ultraviolet (UV) disinfection of drinking water is an effective and increasingly popular method to inactivate chlorine-resistant pathogens of public health concern. In Canada, UV treats over 21% of all drinking water, and recent surveys of treatment facilities identify this technology as a top choice for increasing disinfection effectiveness. Since particulates and other material in natural waters can interfere with the disinfection process by blocking or reflecting light, it is recommended that UV be applied after filtration. However, filtration is not practiced universally, and several unfiltered water supplies utilize UV for disinfection. There are gaps in knowledge regarding UV effectiveness for unfiltered waters, and performance must be well understood under a range of conditions for the protection of public health. The proposed work aims to address knowledge gaps by quantifying relationships between a wide range of unfiltered water quality conditions and UV effectiveness. Two full-scale treatment facilities that apply UV to unfiltered waters will be used as models and to provide representative samples. Disinfection achieved will be identified through standardized microorganism bioassays after exposure to collimated UV light. Using experimental data, the adequacy of current monitoring and operational practices will be considered. This work will also look at ways to improve the accuracy of UV monitoring protocols to ensure that disinfection can be achieved even with challenging source water conditions. Project outcomes will include new data to advance industry best practices in UV disinfection of unfiltered water supplies at Canadian facilities.
Program
Alliance Grants
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
549319-2019
Name nom
Peleato, Nicolas
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2019
Award amount
29573
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
1500
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Environmental engineering
Research subject fr
Génie de l'environnement
Installment
inst:2
Partie
1
Nb partie
2
Application title
Assessment of ultraviolet disinfection for unfiltered water supplies
Keyword
NSERC
Application summary
Ultraviolet (UV) disinfection of drinking water is an effective and increasingly popular method to inactivate chlorine-resistant pathogens of public health concern. In Canada, UV treats over 21% of all drinking water, and recent surveys of treatment facilities identify this technology as a top choice for increasing disinfection effectiveness. Since particulates and other material in natural waters can interfere with the disinfection process by blocking or reflecting light, it is recommended that UV be applied after filtration. However, filtration is not practiced universally, and several unfiltered water supplies utilize UV for disinfection. There are gaps in knowledge regarding UV effectiveness for unfiltered waters, and performance must be well understood under a range of conditions for the protection of public health. The proposed work aims to address knowledge gaps by quantifying relationships between a wide range of unfiltered water quality conditions and UV effectiveness. Two full-scale treatment facilities that apply UV to unfiltered waters will be used as models and to provide representative samples. Disinfection achieved will be identified through standardized microorganism bioassays after exposure to collimated UV light. Using experimental data, the adequacy of current monitoring and operational practices will be considered. This work will also look at ways to improve the accuracy of UV monitoring protocols to ensure that disinfection can be achieved even with challenging source water conditions. Project outcomes will include new data to advance industry best practices in UV disinfection of unfiltered water supplies at Canadian facilities.