Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Université Laval

$25,000.00

Durability study on reinforced concrete axial members retrofitted with fibre-reinforced cementitious matrix (FRCM)**********

FY 2018-19

Summary
Fabric-reinforced cementitious matrix (FRCM) is a retrofitting system that has been introduced recently to retrofit/strengthen reinforced concrete (RC) structures. FRCM consists of one or more layers of anti-corrosive textiles made of carbon, glass, or Polyparaphenylene benzobisoxazole (PBO) grids that are sandwiched between layers of cementitious mortars. Unlike the epoxy-based fiber-reinforced polymers, mortars used in FRCM systems inherit the compatibility between the system and the concrete substrate since both materials have the cement as a common ""base"". To date, no data is available on the aging performance of FRCM-wrapped RC elements under the combined effect of axial loading and the exposure to harsh environmental conditions. The proposed research aims at examining such performance through a series of laboratory tests that will be conducted on RC prisms and cylinders wrapped with FRCM and tested under axial loads. The test parameters include the specimen's cross section (square and circular), the type of FRCM systems (2 types), the number of FRCM layers (1 or 2 layers), the specimen's condition prior to wrapping (conditioned or unconditioned), and the exposure condition after wrapping, which include (1) freeze-and-thaw cycles, (2) high temperatures, (3) humidity and high temperatures, (4) alkali solution, and (5) saltwater. Unconditioned specimens will be tested for reference. Specimens will be instrumented with strain gauges and/or compressometers to monitor the loads and strains during the test until failure occurs. Experimental results in terms of capacity, debonding, straining, modulus, and ductility will be recorded. The effect of different exposures on such quantities will be determined and verified against the provisions of ACI-549.4R-13. The results would be used to develop conceptual design rules for FRCM systems, which consider the effect of environmental aging in RC compression members such as columns and walls.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
537318-2018
Name nom
ELREFAI, AHMED
Department département
Génie civil et génie des eaux
Organization id
51
Institution établissement
Université Laval
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Durability study on reinforced concrete axial members retrofitted with fibre-reinforced cementitious matrix (FRCM)**********
Keyword
NSERC
Application summary
Fabric-reinforced cementitious matrix (FRCM) is a retrofitting system that has been introduced recently to retrofit/strengthen reinforced concrete (RC) structures. FRCM consists of one or more layers of anti-corrosive textiles made of carbon, glass, or Polyparaphenylene benzobisoxazole (PBO) grids that are sandwiched between layers of cementitious mortars. Unlike the epoxy-based fiber-reinforced polymers, mortars used in FRCM systems inherit the compatibility between the system and the concrete substrate since both materials have the cement as a common ""base"". To date, no data is available on the aging performance of FRCM-wrapped RC elements under the combined effect of axial loading and the exposure to harsh environmental conditions. The proposed research aims at examining such performance through a series of laboratory tests that will be conducted on RC prisms and cylinders wrapped with FRCM and tested under axial loads. The test parameters include the specimen's cross section (square and circular), the type of FRCM systems (2 types), the number of FRCM layers (1 or 2 layers), the specimen's condition prior to wrapping (conditioned or unconditioned), and the exposure condition after wrapping, which include (1) freeze-and-thaw cycles, (2) high temperatures, (3) humidity and high temperatures, (4) alkali solution, and (5) saltwater. Unconditioned specimens will be tested for reference. Specimens will be instrumented with strain gauges and/or compressometers to monitor the loads and strains during the test until failure occurs. Experimental results in terms of capacity, debonding, straining, modulus, and ductility will be recorded. The effect of different exposures on such quantities will be determined and verified against the provisions of ACI-549.4R-13. The results would be used to develop conceptual design rules for FRCM systems, which consider the effect of environmental aging in RC compression members such as columns and walls.