Grant: Collaborative Research and Development Grants
Université de Montréal
$75,640.00
Computer simulation decision tool for personalized shoulder orthotic fitting
FY 2010-11
Summary
SUMMARY OF PROPOSAL FOR PUBLIC RELEASE (Use plain language.)
Version française disponible
Shoulder injuries and especially rotator cuff muscle tears are ranked among the most common musculoskeletal
injuries in Quebec. They are characterized by surgical treatments, long- term convalescences, and high
indemnity disbursements. Shoulder orthoses for postoperative arm immobilization vary widely from one
manufacturer to another because there is no literature-based evidence on the optimal arm position and the
permissible range of motion. The main objectives of this collaborative research between Université de
Montréal and Laboratoire Orthopédique Médicus are to determine the sheltered arm position and safe range of
motion to speed up healing and rehabilitation processes. The optimal personalized arm position will be
determined by collecting biomechanical data from 20 able-bodied subjects and 98 patients using a modified
version of the Stanford VA Upper Limb musculoskeletal model. These modifications will include the complete
kinematics of the shoulder complex and contact forces applied by the orthosis to the forearm. Computer
simulations with the musculoskeletal model will be performed for several upper-limb positions fitted with the
shoulder orthosis to minimize the force in the repaired muscles. Afterwards, a search near the optimal positions
will be performed to determine the safe range of motion and permissible exercises with the functional orthosis.
This information will then be used for the fabrication of a personalized shoulder orthosis. Its performance will
be compared to two other commercial shoulder orthoses. From this method, a computer tool will be developed
to personalize and fabricate a shoulder orthosis and to assist orthosists and surgeons. With this technology
Médicus will not only have an original functional orthosis that can safely allow movements at all joints of the
shoulder complex but also have an on-line tool to best adapt existing shoulder orthoses as well. This project
will contribute to the health of Canadians as well as to the development of musculoskeletal models and
improve our understanding of the shoulder complex, and make Médicus the first Canadian company to produce
a shoulder orthosis.
Program
Collaborative Research and Development Grants
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
396803-2010
Name nom
Begon, Mickael
Department département
Kinésiologie
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
75640
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Partie
1
Nb partie
3
Application title
Computer simulation decision tool for personalized shoulder orthotic fitting
Keyword
NSERC
Application summary
SUMMARY OF PROPOSAL FOR PUBLIC RELEASE (Use plain language.)
Version française disponible
Shoulder injuries and especially rotator cuff muscle tears are ranked among the most common musculoskeletal
injuries in Quebec. They are characterized by surgical treatments, long- term convalescences, and high
indemnity disbursements. Shoulder orthoses for postoperative arm immobilization vary widely from one
manufacturer to another because there is no literature-based evidence on the optimal arm position and the
permissible range of motion. The main objectives of this collaborative research between Université de
Montréal and Laboratoire Orthopédique Médicus are to determine the sheltered arm position and safe range of
motion to speed up healing and rehabilitation processes. The optimal personalized arm position will be
determined by collecting biomechanical data from 20 able-bodied subjects and 98 patients using a modified
version of the Stanford VA Upper Limb musculoskeletal model. These modifications will include the complete
kinematics of the shoulder complex and contact forces applied by the orthosis to the forearm. Computer
simulations with the musculoskeletal model will be performed for several upper-limb positions fitted with the
shoulder orthosis to minimize the force in the repaired muscles. Afterwards, a search near the optimal positions
will be performed to determine the safe range of motion and permissible exercises with the functional orthosis.
This information will then be used for the fabrication of a personalized shoulder orthosis. Its performance will
be compared to two other commercial shoulder orthoses. From this method, a computer tool will be developed
to personalize and fabricate a shoulder orthosis and to assist orthosists and surgeons. With this technology
Médicus will not only have an original functional orthosis that can safely allow movements at all joints of the
shoulder complex but also have an on-line tool to best adapt existing shoulder orthoses as well. This project
will contribute to the health of Canadians as well as to the development of musculoskeletal models and
improve our understanding of the shoulder complex, and make Médicus the first Canadian company to produce
a shoulder orthosis.