Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Manitoba

$25,000.00

Partial discharge source classification based on analyzing pd pulse waveforms using statistical pattern recognition techniques

FY 2016-17

Summary
Safe, stable, and reliable electric power systems rely on solid, liquid, and gaseous insulation materials to isolateenergized components from other components and the ground. These materials age over time. When insulationmaterials are under electrical stresses during operation, the generated electric field can cause partial discharges(PDs) which is the beginning of a much faster deterioration. Monitoring partial discharges, as a symptom ofinsulation deterioration, can be used to improve the reliability of high voltage (HV) insulation. Early detectionof PD activities prevents costly failures of electrical equipment. In this proposal, design, development, andtesting of a comprehensive and automated classification system for single and multiple simultaneouslyactivated PD sources identification based on the relationship between the variation of PD pulse waveforms andthe source of PD was proposed. The proposed automated classification system resolves the need of electricpower system industry in term of diagnosing defective insulation systems and also classifying the type ofdefects. Such measurement and classification would have the capability to be performed in both online or offline modes in order to prevent costly failures due to HV apparatus breakdowns. Availability of this automatedclassification system is useful to perform 24/7 continuous monitoring of equipment, which facilitates PDsource identification in early stages and guarantees safe operation of HV apparatus. The proposed projectsupports Manitoba Hydro's desire to automate classification system for PD source recognition and conduct riskassessment of different sources of PD when occurring in different HV apparatus. The outcome of this projectwill benefit Manitoba hydro by increasing power systems security by contributing to the minimization of poweroutages and disruptions due to insulation system failure.
Program
Engage Grants Program
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
499895-2016
Name nom
JafariJozani, Mohammad
Department département
Statistics
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
3004
Research subject group en
Statistics and probability
Research subject group fr
Statistique et probabilité
Research subject en
Applied statistics
Research subject fr
Statistique appliquée
Partie
1
Nb partie
1
Application title
Partial discharge source classification based on analyzing pd pulse waveforms using statistical pattern recognition techniques
Keyword
NSERC
Application summary
Safe, stable, and reliable electric power systems rely on solid, liquid, and gaseous insulation materials to isolateenergized components from other components and the ground. These materials age over time. When insulationmaterials are under electrical stresses during operation, the generated electric field can cause partial discharges(PDs) which is the beginning of a much faster deterioration. Monitoring partial discharges, as a symptom ofinsulation deterioration, can be used to improve the reliability of high voltage (HV) insulation. Early detectionof PD activities prevents costly failures of electrical equipment. In this proposal, design, development, andtesting of a comprehensive and automated classification system for single and multiple simultaneouslyactivated PD sources identification based on the relationship between the variation of PD pulse waveforms andthe source of PD was proposed. The proposed automated classification system resolves the need of electricpower system industry in term of diagnosing defective insulation systems and also classifying the type ofdefects. Such measurement and classification would have the capability to be performed in both online or offline modes in order to prevent costly failures due to HV apparatus breakdowns. Availability of this automatedclassification system is useful to perform 24/7 continuous monitoring of equipment, which facilitates PDsource identification in early stages and guarantees safe operation of HV apparatus. The proposed projectsupports Manitoba Hydro's desire to automate classification system for PD source recognition and conduct riskassessment of different sources of PD when occurring in different HV apparatus. The outcome of this projectwill benefit Manitoba hydro by increasing power systems security by contributing to the minimization of poweroutages and disruptions due to insulation system failure.