Grant: Collaborative Research and Development Grants
McGill University
$63,250.00
Advanced computational modelling for vibration mitigation in guyed towers
FY 2011-12
Summary
The proposed research combines the expertise of McGill University in advanced computational procedures for dynamic analysis of cable structures, with the experimental expertise of IREQ (Hydro Québec Research Institute) in cable vibration measurements. The goal is to develop, validate and test an accurate modeling procedure to study the dynamic response of flexible guyed transmission towers with due consideration of conductor-tower-foundation-soil interactions. Calibrated numerical models will serve to develop vibration mitigation solutions for high voltage line supports exposed to severe combined wind and atmospheric icing loads. Hydro Québec's short-term need is the mitigation of vibrations in guy wires which cause fatigue in rock anchor rods, thus reducing their useful life with potential premature and unpredictable failure. A thorough
analysis of stress wave propagation effects in vibrating guy cables is necessary to understand how the energy is transferred and dissipated at guy cable interfaces with the tower and the ground/rock anchor. Such knowledge is not yet available. Current mitigation practice is to extrapolate empirical passive damping models developed for overhead conductors; this has had only limited success as guy anchor bars and damping devices continue to fail under conditions that the present damping models cannot explain. A novel approach is proposed based on using detailed computational models of guyed supports to characterize the dynamic sensitivity of tower components in terms of the main structural parameters (geometry, stiffness, cable anchor properties, soil-anchor interactions, natural frequencies and internal damping) and the loading conditions. Model validation will proceed by comparison of system properties obtained from in-situ ambient vibration measurements (AVM) on real towers. This research will also benefit other electric power utilities in Canada and abroad as it will provide a tool to study several other complex dynamic problems in guyed supports. Such studies could lead to the design of various efficient failure containment solutions which are paramount to transmission line security and global power grid reliability.
Program
Collaborative Research and Development Grants
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
396079-2009
Name nom
McClure, Ghyslaine
Department département
Civil Engineering and Applied Mechanics
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2009
Award amount
63250
Program id
CRDPJ
Program nane en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
1104
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural analysis
Research subject fr
Analyse des structures
Partie
2
Nb partie
4
Application title
Advanced computational modelling for vibration mitigation in guyed towers
Keyword
NSERC
Application summary
The proposed research combines the expertise of McGill University in advanced computational procedures for dynamic analysis of cable structures, with the experimental expertise of IREQ (Hydro Québec Research Institute) in cable vibration measurements. The goal is to develop, validate and test an accurate modeling procedure to study the dynamic response of flexible guyed transmission towers with due consideration of conductor-tower-foundation-soil interactions. Calibrated numerical models will serve to develop vibration mitigation solutions for high voltage line supports exposed to severe combined wind and atmospheric icing loads. Hydro Québec's short-term need is the mitigation of vibrations in guy wires which cause fatigue in rock anchor rods, thus reducing their useful life with potential premature and unpredictable failure. A thorough
analysis of stress wave propagation effects in vibrating guy cables is necessary to understand how the energy is transferred and dissipated at guy cable interfaces with the tower and the ground/rock anchor. Such knowledge is not yet available. Current mitigation practice is to extrapolate empirical passive damping models developed for overhead conductors; this has had only limited success as guy anchor bars and damping devices continue to fail under conditions that the present damping models cannot explain. A novel approach is proposed based on using detailed computational models of guyed supports to characterize the dynamic sensitivity of tower components in terms of the main structural parameters (geometry, stiffness, cable anchor properties, soil-anchor interactions, natural frequencies and internal damping) and the loading conditions. Model validation will proceed by comparison of system properties obtained from in-situ ambient vibration measurements (AVM) on real towers. This research will also benefit other electric power utilities in Canada and abroad as it will provide a tool to study several other complex dynamic problems in guyed supports. Such studies could lead to the design of various efficient failure containment solutions which are paramount to transmission line security and global power grid reliability.