Grant: Discovery Grants Program - Individual
University of British Columbia
$28,000.00
Moment Resistance Performance of Dowel Based Connections in Wood Products
FY 2018-19
Summary
The moment resistance of bolted connections in wood is poor due to the low tension perpendicular to grain and longitudinal shear strengths of wood. As a practical solution designers may sometimes consider such connections as pinned to only carry shear and axial forces and ignore their moment carrying capacity. The problem is that the wood does not know that it is not supposed to carry moment and could perform poorly even under the intended loading. Alternatively, very slender bolts/dowels can be used with large spacing and end distances which may not be very economical. Rational design guidance is needed to allow bolted moment connection to be used efficiently and safely. The fundamental problem is that the interacting effect of shear and tension perpendicular stresses is not well understood for wood and modern wood products. Both modes of failure are brittle in nature and as a natural material the strength properties of wood are nonhomogeneous and random. These features lead to the fact that tensile perpendicular to grain and longitudinal shear strengths are both sensitive to stressed volume. The larger the stressed volume, the lower the strength. Comprehensive data is not available on the effect of stressed volume on these interacting stresses. Furthermore, the influence of reverse cyclic loading on these strength properties as in the case of demands from earthquakes have not been fully studied.*The proposed work will study the moment carrying capacity of bolted moment connections under monotonic and reverse cyclic loading as components and in structural frames. The interacting brittle failure mode of tension perpendicular to grain and shear will be studied with consideration of stressed volume effect. This information will lead to design guidance for effective reinforcement techniques. Finally, reliability based design procedures will be developed to qualify their performance to handle demands from both seismic and non-seismic loading. The expected impact of the study is more rational design procedures for consideration of bolted and dowel based moment connections leading to safer and more cost efficient design solutions using generic non-proprietary based connectors. Successful implementation of the results will lead to better and safer wood-based buildings especially for the bigger and taller wood building market.
Program
Discovery Grants Program - Individual
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2017-04898
Name nom
Lam, Frank
Department département
Wood Science
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2017
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1107
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Earthquake engineering
Research subject fr
Génie parasismique
Partie
2
Nb partie
5
Application title
Moment Resistance Performance of Dowel Based Connections in Wood Products
Keyword
NSERC
Application summary
The moment resistance of bolted connections in wood is poor due to the low tension perpendicular to grain and longitudinal shear strengths of wood. As a practical solution designers may sometimes consider such connections as pinned to only carry shear and axial forces and ignore their moment carrying capacity. The problem is that the wood does not know that it is not supposed to carry moment and could perform poorly even under the intended loading. Alternatively, very slender bolts/dowels can be used with large spacing and end distances which may not be very economical. Rational design guidance is needed to allow bolted moment connection to be used efficiently and safely. The fundamental problem is that the interacting effect of shear and tension perpendicular stresses is not well understood for wood and modern wood products. Both modes of failure are brittle in nature and as a natural material the strength properties of wood are nonhomogeneous and random. These features lead to the fact that tensile perpendicular to grain and longitudinal shear strengths are both sensitive to stressed volume. The larger the stressed volume, the lower the strength. Comprehensive data is not available on the effect of stressed volume on these interacting stresses. Furthermore, the influence of reverse cyclic loading on these strength properties as in the case of demands from earthquakes have not been fully studied.*The proposed work will study the moment carrying capacity of bolted moment connections under monotonic and reverse cyclic loading as components and in structural frames. The interacting brittle failure mode of tension perpendicular to grain and shear will be studied with consideration of stressed volume effect. This information will lead to design guidance for effective reinforcement techniques. Finally, reliability based design procedures will be developed to qualify their performance to handle demands from both seismic and non-seismic loading. The expected impact of the study is more rational design procedures for consideration of bolted and dowel based moment connections leading to safer and more cost efficient design solutions using generic non-proprietary based connectors. Successful implementation of the results will lead to better and safer wood-based buildings especially for the bigger and taller wood building market.