Grant: Research Tools and Instruments
University of Toronto
$150,000.00
A Magnetic Microrobotic System with Raman Spectroscopy and Confocal Fluorescence Microscopy for Molecular Diagnostics and Cell Biology
FY 2020-21
Summary
Magnetically controlled microrobots represent a promising platform technology for manipulation and characterization of cells and biomolecules. Current magnetic microrobotic systems typically involve brightfield/fluorescence microscopy or ultrasound imaging as visual feedback, which cannot retrieve any biochemical information of the bio-sample under manipulation. This application aims to establish the first magnetic microrobotic system seamlessly integrating both Raman spectroscopy and confocal fluorescence microscopy, for simultaneous manipulation of intracellular organelles/biomolecules and characterization their biophysical and biochemical properties. The unique combination of the Raman and confocal fluorescence imaging modalities provides the microrobotic system with both biophysical and biochemical feedback and allows novel applications in molecular diagnostics and cell biology.
The proposed microrobotic system includes: (1) a Raman imaging system based on an inverted microscope for biochemical characterization of bio-samples; (2) a custom-made, coil-based electromagnetic control module for positioning of magnetic bead-based microrobots with sub-micrometer resolution; and (3) a laser scanning confocal fluorescence imaging module, which can be readily integrated onto the inverted microscope of the Raman imaging system, for 3D imaging of the magnetic bead-based microrobot and the bio-sample. With CFI and NSERC Discovery Grant support, the applicants have purchased a Raman imaging system with an inverted microscope, and developed a custom-made electromagnetic control module. This RTI application is to request the laser scanning confocal fluorescence module for integration with the Raman imaging system.
Using this unique system, we will pursue the following research projects: (1) microrobotic capture, enrichment, and amplification-free detection of the novel coronavirus (severe acute respiratory syndrome coronavirus 2 SARS-CoV-2); (2) microfluidic characterization of nucleus mechanics and associated molecular mechanisms of brain cancer cells; and (3) label-free detection and spatial profiling of signaling molecules during microfluidic cell co-culture. The requested confocal fluorescence imaging module will be used for: (1) vertical scanning of fluorecence signals from a magnetic bead for amplification-free detection of SARS-CoV-2; (2) 3D imaging of a magnetic bead-based microrobot inside a brain cancer cell and the cell's nuclear deformation during magentic bead indentation; and (3) fluorecence imaging of bone cells (osteocytes) and bone resorption cells (osteoclasts) co-cultured on a microfluidic device. This system be used for training 15 HQPs from 8 research labs, and will serve as a powerful multifunctional facility to enable new collaborations at the interface of robotics, diagnostics and cell research.
Program
Research Tools and Instruments
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RTI-2021-00769
Name nom
Liu, Xinyu
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2021
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1612
Committee name en
Mechanical Engineering (RTI)
Committee name fr
Génie mecanique (OIR)
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Installment
inst:1-1
Partie
1
Nb partie
1
Application title
A Magnetic Microrobotic System with Raman Spectroscopy and Confocal Fluorescence Microscopy for Molecular Diagnostics and Cell Biology
Keyword
NSERC
Application summary
Magnetically controlled microrobots represent a promising platform technology for manipulation and characterization of cells and biomolecules. Current magnetic microrobotic systems typically involve brightfield/fluorescence microscopy or ultrasound imaging as visual feedback, which cannot retrieve any biochemical information of the bio-sample under manipulation. This application aims to establish the first magnetic microrobotic system seamlessly integrating both Raman spectroscopy and confocal fluorescence microscopy, for simultaneous manipulation of intracellular organelles/biomolecules and characterization their biophysical and biochemical properties. The unique combination of the Raman and confocal fluorescence imaging modalities provides the microrobotic system with both biophysical and biochemical feedback and allows novel applications in molecular diagnostics and cell biology.
The proposed microrobotic system includes: (1) a Raman imaging system based on an inverted microscope for biochemical characterization of bio-samples; (2) a custom-made, coil-based electromagnetic control module for positioning of magnetic bead-based microrobots with sub-micrometer resolution; and (3) a laser scanning confocal fluorescence imaging module, which can be readily integrated onto the inverted microscope of the Raman imaging system, for 3D imaging of the magnetic bead-based microrobot and the bio-sample. With CFI and NSERC Discovery Grant support, the applicants have purchased a Raman imaging system with an inverted microscope, and developed a custom-made electromagnetic control module. This RTI application is to request the laser scanning confocal fluorescence module for integration with the Raman imaging system.
Using this unique system, we will pursue the following research projects: (1) microrobotic capture, enrichment, and amplification-free detection of the novel coronavirus (severe acute respiratory syndrome coronavirus 2 SARS-CoV-2); (2) microfluidic characterization of nucleus mechanics and associated molecular mechanisms of brain cancer cells; and (3) label-free detection and spatial profiling of signaling molecules during microfluidic cell co-culture. The requested confocal fluorescence imaging module will be used for: (1) vertical scanning of fluorecence signals from a magnetic bead for amplification-free detection of SARS-CoV-2; (2) 3D imaging of a magnetic bead-based microrobot inside a brain cancer cell and the cell's nuclear deformation during magentic bead indentation; and (3) fluorecence imaging of bone cells (osteocytes) and bone resorption cells (osteoclasts) co-cultured on a microfluidic device. This system be used for training 15 HQPs from 8 research labs, and will serve as a powerful multifunctional facility to enable new collaborations at the interface of robotics, diagnostics and cell research.