Grant: Engage Grants Program
McMaster University
$25,000.00
Development of a high performance standoff radiation detection system (SORD)
FY 2015-16
Summary
The detection of nuclear threat is a critical component of Canada's national security network. Being able to detect small amounts of radiation at large distances is especially important in a wide range of applications including homeland security, customs and border protection, emergency response to nuclear accidents, and military tasks on the battlefield. Tools currently exist but they are sub-optimal. In order to optimally use the manpower and resources currently available for radiological response, a highly sensitive radiation detection device, which can rapidly determine the type and location of the radiation source term from a distant location (~10-50 meters), is desired. The basic requirements for such a device are high sensitivity, high dynamic range, low mass, portable unit with spectrographic capabilities among others. Many of these
requirements are shared with radiation technology that is widely used in medical physics imaging applications and as a result, there is an excellent opportunity to capitalize on the decades of operational experience and optimization that has occurred in the medical physics area. Of particular interest is the fact that medical imaging techniques such as Positron Emission Tomography (PET) also require rapid acquisition of spectral and directional photon flux profiles in a confined space. These requirements translate into directional detection capability, high detection cross section to volume ratio, high-count rate capability and energy dispersive measurement, all of which map directly into the basic requirements of an Intelligent Radiation Mapping Device (IRMD). Our long-term goal is to develop a high performance standoff radiation detection system (SORDS) using novel scintillators and silicon photomultipliers (SiPMs), with unique depth-of-interaction (DOI) design and spatial localization algorithm. For this 6-month propjet, the deliverable is to prove the feasibility of a novel SiPM-based detector module.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
479768-2015
Name nom
Peng, Hao
Department département
Medical Physics & Applied Radiation Sciences
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
3102
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Nuclear physics
Research subject fr
Physique nucléaire
Partie
1
Nb partie
1
Application title
Development of a high performance standoff radiation detection system (SORD)
Keyword
NSERC
Application summary
The detection of nuclear threat is a critical component of Canada's national security network. Being able to detect small amounts of radiation at large distances is especially important in a wide range of applications including homeland security, customs and border protection, emergency response to nuclear accidents, and military tasks on the battlefield. Tools currently exist but they are sub-optimal. In order to optimally use the manpower and resources currently available for radiological response, a highly sensitive radiation detection device, which can rapidly determine the type and location of the radiation source term from a distant location (~10-50 meters), is desired. The basic requirements for such a device are high sensitivity, high dynamic range, low mass, portable unit with spectrographic capabilities among others. Many of these
requirements are shared with radiation technology that is widely used in medical physics imaging applications and as a result, there is an excellent opportunity to capitalize on the decades of operational experience and optimization that has occurred in the medical physics area. Of particular interest is the fact that medical imaging techniques such as Positron Emission Tomography (PET) also require rapid acquisition of spectral and directional photon flux profiles in a confined space. These requirements translate into directional detection capability, high detection cross section to volume ratio, high-count rate capability and energy dispersive measurement, all of which map directly into the basic requirements of an Intelligent Radiation Mapping Device (IRMD). Our long-term goal is to develop a high performance standoff radiation detection system (SORDS) using novel scintillators and silicon photomultipliers (SiPMs), with unique depth-of-interaction (DOI) design and spatial localization algorithm. For this 6-month propjet, the deliverable is to prove the feasibility of a novel SiPM-based detector module.