Grant: Alliance Grants
Université de Sherbrooke
$45,000.00
High-resolution ultrasound imaging of micro-bubble cavitation using separate emission / reception transducers
FY 2022-23
Summary
The use of microbubbles or cavitation agents has enabled a wide and rapidly expanding field of research, with their benefits being repeatedly demonstrated, both in localized drug delivery applications and ultrasound image enhancement. In both cases, the oscillations of microbubbles are exploited but their effects may vary depending on the ultrasound frequency and intensity. At low ultrasound intensities, the microbubbles oscillate in a stable motion, also known as stable cavitation, inducing linear reflection and harmonic response to an incident ultrasound field. In contrast, at higher ultrasound intensities, inertial cavitation characterized by rapid growth and collapse of the microbubbles occur, and is thus characterized by an extended bandwidth. Since high intensity ultrasound can cause irreversible thermal damage to tissue, inertial cavitation should be prevented, and the local intensity thus controlled. For this purpose, a dual system capable of focusing and monitoring the local intensity is required at the targeted area.Existing dual systems are based on the use of classical beamforming algorithms and dedicated ultrasound probe used for both cavitation and imaging with a central frequency selected to induce stable cavitation. However, due to the limited bandwidth of existing ultrasound probes, the harmonic imaging is often limited to the second harmonic. Other technologies based on the separation of therapeutic and imaging transducers have been proposed in the literature for low- and high-intensity focused ultrasound. Those assemblies allow separation of emission and reception but are cumbersome and limited in resolution, and thus not adapted to drug delivery or imaging within complex loci where the access window is limited to 1 cm2 at best (spinal cord or temporal bone window for instance). Moreover, in the case of constrained areas, surroundings organs (bones, interfaces) induce reflections, refraction and diffusion of ultrasound waves that may influence the focusing and imaging performance. Based on these observations, two challenges should be addressed in order to better exploit contrast agents in the case of complex loci for both focalization and imaging: 1) the design and manufacturing of dedicated compact transducers and 2) the adaptation of imaging algorithms for cavitation regime tracking with a limited data bandwidth. This research project is thus organized following three distinct thrusts, conducted in parallel by 2 PhD and 1 MASc students, that aim 1) to propose novel compact transducer design based on separate emission / reception and spatial compounding, 2) to adapt existing micro-machining techniques for compact theranostic transducer assemblies and 3) to develop high-resolution correlation-based imaging techniques for contrast agent imaging in complex media. Different applications will be considered using numerical simulations and in-vitro phantoms such as: spinal cord for which multiple reflections at the vertebra impair the imaging and focusing, and contrast agent-based transcranial applications for which the phase and amplitude aberrations induced by the transmission through the skull will be considered. Real-time implementation for clinical and pre-clinical researchers on a commercial ultrasound prototyping platform (Verasonics Vantage) will be achieved for use in a further project.
Program
Alliance Grants
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
571518-2021
Name nom
Quaegebeur, Nicolas NCP
Department département
Génie mécanique
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2021
Award amount
45000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Installment
inst:2
Partie
1
Nb partie
2
Application title
High-resolution ultrasound imaging of micro-bubble cavitation using separate emission / reception transducers
Application summary
The use of microbubbles or cavitation agents has enabled a wide and rapidly expanding field of research, with their benefits being repeatedly demonstrated, both in localized drug delivery applications and ultrasound image enhancement. In both cases, the oscillations of microbubbles are exploited but their effects may vary depending on the ultrasound frequency and intensity. At low ultrasound intensities, the microbubbles oscillate in a stable motion, also known as stable cavitation, inducing linear reflection and harmonic response to an incident ultrasound field. In contrast, at higher ultrasound intensities, inertial cavitation characterized by rapid growth and collapse of the microbubbles occur, and is thus characterized by an extended bandwidth. Since high intensity ultrasound can cause irreversible thermal damage to tissue, inertial cavitation should be prevented, and the local intensity thus controlled. For this purpose, a dual system capable of focusing and monitoring the local intensity is required at the targeted area.Existing dual systems are based on the use of classical beamforming algorithms and dedicated ultrasound probe used for both cavitation and imaging with a central frequency selected to induce stable cavitation. However, due to the limited bandwidth of existing ultrasound probes, the harmonic imaging is often limited to the second harmonic. Other technologies based on the separation of therapeutic and imaging transducers have been proposed in the literature for low- and high-intensity focused ultrasound. Those assemblies allow separation of emission and reception but are cumbersome and limited in resolution, and thus not adapted to drug delivery or imaging within complex loci where the access window is limited to 1 cm2 at best (spinal cord or temporal bone window for instance). Moreover, in the case of constrained areas, surroundings organs (bones, interfaces) induce reflections, refraction and diffusion of ultrasound waves that may influence the focusing and imaging performance. Based on these observations, two challenges should be addressed in order to better exploit contrast agents in the case of complex loci for both focalization and imaging: 1) the design and manufacturing of dedicated compact transducers and 2) the adaptation of imaging algorithms for cavitation regime tracking with a limited data bandwidth. This research project is thus organized following three distinct thrusts, conducted in parallel by 2 PhD and 1 MASc students, that aim 1) to propose novel compact transducer design based on separate emission / reception and spatial compounding, 2) to adapt existing micro-machining techniques for compact theranostic transducer assemblies and 3) to develop high-resolution correlation-based imaging techniques for contrast agent imaging in complex media. Different applications will be considered using numerical simulations and in-vitro phantoms such as: spinal cord for which multiple reflections at the vertebra impair the imaging and focusing, and contrast agent-based transcranial applications for which the phase and amplitude aberrations induced by the transmission through the skull will be considered. Real-time implementation for clinical and pre-clinical researchers on a commercial ultrasound prototyping platform (Verasonics Vantage) will be achieved for use in a further project.