Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Alliance Grants

University of Calgary

$50,000.00

A low-cost, effective Differential Multi-Ventilation system for use against COVID-19_x000d_ _x000d_ _x000d_ _x000d_ _x000d_

FY 2020-21

Summary
Ventilator shortages within Canada's healthcare system have become a problem of immediate concern during the COVID-19 pandemic. One solution for the emerging need for additional ventilator capacity is to share a ventilator between multiple patients, called multi-ventilation. This strategy has been used in New York and has received crisis approval by Health and Human Services and the Federal Drug Administration. However, the multi-ventilation system has been restricted for use in major medical organizations due to potential safety risks such as trigger issues between the patients sharing a ventilator. This research project proposes a state-of-art system that enables us to overcome possible safety risks to expand ventilator capacity. A low-cost and effective Differential Multi-Ventilation (DMV) system allows us to permit individualized settings for patients sharing a ventilator by utilizing flow restrictors, sensors, and a controller that allows adjustment and monitoring of inspiratory and expiratory parameters. The DMV system, which consists of 3D-printed adjustable Positive End-Expiratory Pressure (PEEP) valves, can be a cost-saving, configuration-flexible, multi-dimensional alternative. Combining adjustable PEEP valves with sensors, bypass circuits, and a controller will allow us to increase ventilator capacity, reduce the production cost, and provide improved quality patient care compared to the traditional system. The proposed objectives of this research are to understand the system's fluid dynamics and to improve upon the ventilations' current structural challenges. This project's novelties lie in the analysis of the DMV's design parameters, optimization using a genetic algorithm, the application of micro-electromechanical system (MEMS) sensors, a pre-compensation algorithm, and the physical model. This proposal's outcome also provides a configuration guideline, a monitoring and control module, and DMV dynamic simulation software.
Program
Alliance Grants
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
554615-2020
Name nom
Lee, Jihyun
Department département
Mechanical and Manufacturing Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2020
Award amount
50000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2107
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Modelling, simulation and finite element methods
Research subject fr
Modélisation, simulation et méthodes des éléments finis
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
A low-cost, effective Differential Multi-Ventilation system for use against COVID-19_x000d_ _x000d_ _x000d_ _x000d_ _x000d_
Keyword
NSERC
Application summary
Ventilator shortages within Canada's healthcare system have become a problem of immediate concern during the COVID-19 pandemic. One solution for the emerging need for additional ventilator capacity is to share a ventilator between multiple patients, called multi-ventilation. This strategy has been used in New York and has received crisis approval by Health and Human Services and the Federal Drug Administration. However, the multi-ventilation system has been restricted for use in major medical organizations due to potential safety risks such as trigger issues between the patients sharing a ventilator. This research project proposes a state-of-art system that enables us to overcome possible safety risks to expand ventilator capacity. A low-cost and effective Differential Multi-Ventilation (DMV) system allows us to permit individualized settings for patients sharing a ventilator by utilizing flow restrictors, sensors, and a controller that allows adjustment and monitoring of inspiratory and expiratory parameters. The DMV system, which consists of 3D-printed adjustable Positive End-Expiratory Pressure (PEEP) valves, can be a cost-saving, configuration-flexible, multi-dimensional alternative. Combining adjustable PEEP valves with sensors, bypass circuits, and a controller will allow us to increase ventilator capacity, reduce the production cost, and provide improved quality patient care compared to the traditional system. The proposed objectives of this research are to understand the system's fluid dynamics and to improve upon the ventilations' current structural challenges. This project's novelties lie in the analysis of the DMV's design parameters, optimization using a genetic algorithm, the application of micro-electromechanical system (MEMS) sensors, a pre-compensation algorithm, and the physical model. This proposal's outcome also provides a configuration guideline, a monitoring and control module, and DMV dynamic simulation software.