Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments - Category 1 (<$150,000)

Dalhousie University

$19,242.00

Source to enable high resolution APCI mass spectrometry

FY 2009-10

Summary
Funds are requested to acquire an atmospheric pressure chemical ionization (APCI) source to fit into an existing Bruker MicroTOF (time-of-flight) mass spectrometer that is capable of acquiring high resolution data. In 2006 the Dalhousie University Department of Chemistry Mass Spectrometry Facility was granted NSERC funds with which to purchase a MicroTOF mass spectrometer and it is for this instrument that an APCI source is being sought: this acquisition would make this NSERC-funded instrument extremely versatile and even better value. Mass spectrometry provides scientists with information regarding the molecular mass of molecules. High resolution mass spectrometry can help scientists to decipher the likely molecular formula of molecules, and this is of significant assistance when characterizing molecules that are new. APCI mass spectrometry is particularly useful for the analysis of molecules that do not protonate easily and for which alternative modes of ionization are unsuccessful. Many of the molecules analyzed in the Dalhousie University Department of Chemistry Mass Spectrometry Facility are non-polar and thus unsuitable for investigation via electrospray ionization (ESI) whereby protonation (or "sodiation") is a pivotal requirement. Presently, the MicroTOF mass spectrometer can only give high resolution mass spectral information when operating under ESI mode, and this is a clear limiting factor: provision of the requested APCI source would significantly enhance the quality and quantity of research stemming from synthetic and analytical chemistry projects. The APCI source would be used by around twenty research groups at Dalhousie University, plus others from other Maritime universities and beyond (e.g., regular users of services from Acadia University, St. Francis Xavier University, University of New Brunswick, University of Mannitoba).
Program
Research Tools and Instruments - Category 1 (<$150,000)
Location
Nova Scotia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
390298-2010
Name nom
Thompson, Alison
Department département
Chemistry
Organization id
79
Institution établissement
Dalhousie University
Province en
Nova Scotia
Province fr
Nouvelle-Écosse
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2010
Award amount
19242
Program id
EQPEQ
Program nane en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1504
Committee name en
Chemistry
Committee name fr
Chimie
Area of application code
1202
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Physical sciences
Area of application fr
Sciences physiques
Research subject code
3500
Research subject group en
Analytical chemistry
Research subject group fr
Chimie analytique
Research subject en
Analytical chemistry
Research subject fr
Chimie analytique
Partie
1
Nb partie
1
Application title
Source to enable high resolution APCI mass spectrometry
Keyword
NA
Application summary
Funds are requested to acquire an atmospheric pressure chemical ionization (APCI) source to fit into an existing Bruker MicroTOF (time-of-flight) mass spectrometer that is capable of acquiring high resolution data. In 2006 the Dalhousie University Department of Chemistry Mass Spectrometry Facility was granted NSERC funds with which to purchase a MicroTOF mass spectrometer and it is for this instrument that an APCI source is being sought: this acquisition would make this NSERC-funded instrument extremely versatile and even better value. Mass spectrometry provides scientists with information regarding the molecular mass of molecules. High resolution mass spectrometry can help scientists to decipher the likely molecular formula of molecules, and this is of significant assistance when characterizing molecules that are new. APCI mass spectrometry is particularly useful for the analysis of molecules that do not protonate easily and for which alternative modes of ionization are unsuccessful. Many of the molecules analyzed in the Dalhousie University Department of Chemistry Mass Spectrometry Facility are non-polar and thus unsuitable for investigation via electrospray ionization (ESI) whereby protonation (or "sodiation") is a pivotal requirement. Presently, the MicroTOF mass spectrometer can only give high resolution mass spectral information when operating under ESI mode, and this is a clear limiting factor: provision of the requested APCI source would significantly enhance the quality and quantity of research stemming from synthetic and analytical chemistry projects. The APCI source would be used by around twenty research groups at Dalhousie University, plus others from other Maritime universities and beyond (e.g., regular users of services from Acadia University, St. Francis Xavier University, University of New Brunswick, University of Mannitoba).