Grant: Alliance Grants
University of Waterloo
$50,000.00
Catalytic material design for non-enzymatic lactate sensors for detection of anastomotic leaks post-surgery
FY 2024-25
Summary
FluidAI Medical has developed and clinically tested a smart catheter system for detection of anastomotic leakages. Such post-operative anastomotic leaks following surgery in the abdominal region lead to increased mortality rates and post-surgery monitoring costs on the health care system. Multiple sensors are required as anastomotic leaks are not specifically linked to a particular marker but rather a spectrum of indicators such as pH levels, lactate concentration and elevated temperature. However, the current smart catheter from FluidAI Medical lacks the ability to sense lactate which is a crucial early biomarker and is excreted from the leak site prior to development of a full breach. This project aims to optimize the nanoscale morphology of a non-enzymatic lactate sensing material that has been developed in the Maheshwari group. The optimized sensor will be able to detect lactate concentrations in the range of 1 mM to 10 mM in the peritoneal fluid with high specificity and lifetime of ~ 1 week. The development of the lactate sensor is based on the technology developed in the Maheshwari group that combines multiple catalytic elements in a spatial controlled manner on the scale of nanometer. Specificity and lifetime of the sensor will also be optimized by varying the catalyst morphology and the use of surface coatings.
Program
Alliance Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
598491-2024
Name nom
Maheshwari, Vivek V
Department département
Chemistry
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2024
Award amount
50000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Catalytic material design for non-enzymatic lactate sensors for detection of anastomotic leaks post-surgery
Keywords
electrocatalyst; lactate; non-enzymatic sensors; post surgery monitoring; self-assembly; sensing
Application summary
FluidAI Medical has developed and clinically tested a smart catheter system for detection of anastomotic leakages. Such post-operative anastomotic leaks following surgery in the abdominal region lead to increased mortality rates and post-surgery monitoring costs on the health care system. Multiple sensors are required as anastomotic leaks are not specifically linked to a particular marker but rather a spectrum of indicators such as pH levels, lactate concentration and elevated temperature. However, the current smart catheter from FluidAI Medical lacks the ability to sense lactate which is a crucial early biomarker and is excreted from the leak site prior to development of a full breach. This project aims to optimize the nanoscale morphology of a non-enzymatic lactate sensing material that has been developed in the Maheshwari group. The optimized sensor will be able to detect lactate concentrations in the range of 1 mM to 10 mM in the peritoneal fluid with high specificity and lifetime of ~ 1 week. The development of the lactate sensor is based on the technology developed in the Maheshwari group that combines multiple catalytic elements in a spatial controlled manner on the scale of nanometer. Specificity and lifetime of the sensor will also be optimized by varying the catalyst morphology and the use of surface coatings.