Summary
In this proposed project, we will develop a robust strategy to accurately evaluate the hemodynamic performance of transcatheter aortic valves by taking into account their interaction with the native calcified aortic stenosis. This strategy will use a combination of finite element modeling and experimental testing. It will provide a research and development tool which is capable to predict the hemodynamic performance of transcatheter aortic valve prototypes. This project will contribute to ViVitro Labs Inc.'s efforts to overcome the technical challenges that prevent a robust and efficient in vitro test of transcatheter aortic valves performance.
In the proposed research, we will further develop a finite element computational model allowing the simulation of the implantation of any transcatheter aortic valve design prototype in the presence of stenotic valves with different severities. This model will be used to determine, for each severity, the stress distribution on valve stent and the resistive radial force exerted by the stenotic valve. We will also design a module to be incorporated in the Vivitro pulse duplicator in order to perform experimental tests on transcatheter aortic valves. The module will allow simulating realistic implantation conditions by including a silicone model of aortic stenosis with externally adjustable severities.
This project will contribute to the optimization of the development cycle of transcatheter aortic valves and has the potential to give Canadian industry leading role in the emerging and exponentially growing market of transcatheter valve devices.
Program
Engage Grants Program
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
417881-2011
Name nom
Kadem, Lyes
Department département
Mechanical and Industrial Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
24329
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
A robust strategy for evaluating hemodynamic performance of transcatheter aortic valves
Keyword
NSERC
Application summary
In this proposed project, we will develop a robust strategy to accurately evaluate the hemodynamic performance of transcatheter aortic valves by taking into account their interaction with the native calcified aortic stenosis. This strategy will use a combination of finite element modeling and experimental testing. It will provide a research and development tool which is capable to predict the hemodynamic performance of transcatheter aortic valve prototypes. This project will contribute to ViVitro Labs Inc.'s efforts to overcome the technical challenges that prevent a robust and efficient in vitro test of transcatheter aortic valves performance.
In the proposed research, we will further develop a finite element computational model allowing the simulation of the implantation of any transcatheter aortic valve design prototype in the presence of stenotic valves with different severities. This model will be used to determine, for each severity, the stress distribution on valve stent and the resistive radial force exerted by the stenotic valve. We will also design a module to be incorporated in the Vivitro pulse duplicator in order to perform experimental tests on transcatheter aortic valves. The module will allow simulating realistic implantation conditions by including a silicone model of aortic stenosis with externally adjustable severities.