Grant: Engage Grants Program
University of Ontario Institute of Technology
$23,020.00
Development of reactor power transient control module for severe accident scenarios for CANDU nuclear reactors
FY 2014-15
Summary
Large Break Loss of Coolant Accidents (LB LOCA) are defined as those with the loss of coolant rate of 3000 kg s^-1 or higher. Rapid coolant voiding leads to an overpower transient for reactors having positive void reactivity and subsequent possible fuel centreline melting, fuel cladding failure, and possible loss of integrity of fuel channels. Peak reactivity should not exceed the prompt criticality threshold to prevent uncontrolled increase of reactivity and reactor power [1].For the CANDU reactors, PWRs, and, as applicable, for high temperature Generation IV reactors, several options have been evaluated for the potential improvement of reactor power measurements during steady state operation and during reactor transients. Reactor power regulation, reactivity control and reactor trips in the existing design are mainly based on neutronic power signals that are susceptible to signal noise and electromagnetic interference (EMI). False (spurious) channel trips may cause a reactor to trip in certain scenarios resulting in loss of generation. With the combination of selected reactor process parameters and measurement of gamma and thermal neutron fluxes, better control of the reactor power (including spatialpower), with a reduced probability of false trips, can be achieved. In the case of a LB LOCA transient, faster reactor trips will decrease the duration of, or fully eliminate a prompt criticality even in reactors with a positive void reactivity coefficient. The proposed project will provide practical solution to ensure safer CANDU nuclear power plants during LOCA events without the need of additional software or firmware, which will provide easy implementation based on the proposed signal processing and trip logic techniques. Almost all the components required in this solution will be based on existing reactor instrumentation, without any modification to the reactor systems.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
476628-2014
Name nom
Gaber, Hossam
Department département
Energy Systems & Nuclear Science, Faculty of
Organization id
19222
Institution établissement
University of Ontario Institute of Technology
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
23020
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
302
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Nuclear energy
Area of application fr
Énergie nucléaire
Research subject code
2509
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Control systems
Research subject fr
Asservissements
Partie
1
Nb partie
1
Application title
Development of reactor power transient control module for severe accident scenarios for CANDU nuclear reactors
Keyword
NSERC
Application summary
Large Break Loss of Coolant Accidents (LB LOCA) are defined as those with the loss of coolant rate of 3000 kg s^-1 or higher. Rapid coolant voiding leads to an overpower transient for reactors having positive void reactivity and subsequent possible fuel centreline melting, fuel cladding failure, and possible loss of integrity of fuel channels. Peak reactivity should not exceed the prompt criticality threshold to prevent uncontrolled increase of reactivity and reactor power [1].For the CANDU reactors, PWRs, and, as applicable, for high temperature Generation IV reactors, several options have been evaluated for the potential improvement of reactor power measurements during steady state operation and during reactor transients. Reactor power regulation, reactivity control and reactor trips in the existing design are mainly based on neutronic power signals that are susceptible to signal noise and electromagnetic interference (EMI). False (spurious) channel trips may cause a reactor to trip in certain scenarios resulting in loss of generation. With the combination of selected reactor process parameters and measurement of gamma and thermal neutron fluxes, better control of the reactor power (including spatialpower), with a reduced probability of false trips, can be achieved. In the case of a LB LOCA transient, faster reactor trips will decrease the duration of, or fully eliminate a prompt criticality even in reactors with a positive void reactivity coefficient. The proposed project will provide practical solution to ensure safer CANDU nuclear power plants during LOCA events without the need of additional software or firmware, which will provide easy implementation based on the proposed signal processing and trip logic techniques. Almost all the components required in this solution will be based on existing reactor instrumentation, without any modification to the reactor systems.