Grant: Collaborative Research and Development Grants
University of Toronto
$58,000.00
High Efficiency Heat Exchanger for Drain-Water Heat Recovery _x000d_ _x000d_ _x000d_
FY 2020-21
Summary
The average Canadian uses 75 L of hot water per day, over half of which is used for bathing, laundry, and dishwashing. When the waste water produced flows into drains it carries a significant amount of thermal energy with it. One way of recovering some of this energy is to use a drain water heat recovery (DWHR) system, which is a heat exchanger that transfers heat from wastewater to incoming cold city water before it flows into the water heater. Current DWHR systems that are commercially available have a relatively low heat exchange effectiveness. They also have no method of detecting leaks, which could potentially lead to contamination of potable water. Drain water heat recovery systems need a leak detection system that will sound an alert if the wall between the two water streams is ruptured.
The proposed project is a collaboration between the University of Toronto and Lancaster Homes, which is based in Richmond Hill and is one of Ontario's leading residential builders. We will design and build high-efficiency heat exchangers to recover and use the thermal energy from waste hot water, while also developing a safety system to detect when mixing of grey and fresh water lines. The chief objectives of the proposed project are:
- Optimise the design of a high-efficiency shell-and-tube heat exchanger.
- Design a novel falling-film heat exchanger for waste heat recovery
- Build both heat exchangers and test them according to ANSI standards.
- Develop an active leak detection system, to immediately alert the user once mixing of the grey and fresh water lines occurs.
Program
Collaborative Research and Development Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
538447-2018
Name nom
Chandra, Sanjeev
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2018
Award amount
58000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1805
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Transport processes
Research subject fr
Procédés de transfert
Installment
inst:2 - 2
Partie
1
Nb partie
2
Application title
High Efficiency Heat Exchanger for Drain-Water Heat Recovery _x000d_
_x000d_
_x000d_
Keyword
NSERC
Application summary
The average Canadian uses 75 L of hot water per day, over half of which is used for bathing, laundry, and dishwashing. When the waste water produced flows into drains it carries a significant amount of thermal energy with it. One way of recovering some of this energy is to use a drain water heat recovery (DWHR) system, which is a heat exchanger that transfers heat from wastewater to incoming cold city water before it flows into the water heater. Current DWHR systems that are commercially available have a relatively low heat exchange effectiveness. They also have no method of detecting leaks, which could potentially lead to contamination of potable water. Drain water heat recovery systems need a leak detection system that will sound an alert if the wall between the two water streams is ruptured.
The proposed project is a collaboration between the University of Toronto and Lancaster Homes, which is based in Richmond Hill and is one of Ontario's leading residential builders. We will design and build high-efficiency heat exchangers to recover and use the thermal energy from waste hot water, while also developing a safety system to detect when mixing of grey and fresh water lines. The chief objectives of the proposed project are:
- Optimise the design of a high-efficiency shell-and-tube heat exchanger.
- Design a novel falling-film heat exchanger for waste heat recovery
- Build both heat exchangers and test them according to ANSI standards.
- Develop an active leak detection system, to immediately alert the user once mixing of the grey and fresh water lines occurs.