Grant: Engage Grants Program
University of Guelph
$25,000.00
High Resolution X-Ray Diffraction Study of High-Density Polyethylene Subject to Controlled Stress and Temperature
FY 2018-19
Summary
PexCor PEX pipes are manufactured and receive certification for certain service environments (ratings for*pressure, and temperature, proper installation procedure) to ensure adequate rated service life. If a pipe*occasionally fails prematurely PexCor needs to understand the root cause. Unfortunately one cannot install*pressure and temperature sensors in every system to ensure that the service parameters were not exceeded*during operation. X-ray crystallography may give an opportunity to see if there are any resolvable features in*stressed pipe to indicate high stress.*PexCor has the capability to subject PEX pipe to carefully controlled pressure and temperature stresses. A*series of pipe samples with a known stress history will be prepared and provided for the University of Guelph*x-ray diffraction lead by Prof Stefan Kycia. A thorough set of x-ray diffraction and scattering measurements*will be conducted on the samples to see if it is possible to track with the induced stress. X-ray diffraction is*sensitive to the preferred orientation, crystal quality, crystal structure, disorder, amorphous component, and*strain in the high density polyethylene tubing.*Solving this problem will require a thorough x-ray diffraction characterization of the samples. Measurements*will be conducted at the University of Guelph X-Ray Diffraction Laboratory as well as the Brockhouse Sector*at the Canadian Light Source.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
531155-2018
Name nom
Kycia, Stefan
Department département
Physics
Organization id
24
Institution établissement
University of Guelph
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
508
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Polymers, rubber and plastics
Area of application fr
Polymères, caoutchouc et plastiques
Research subject code
2004
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Polymers and coatings
Research subject fr
Polymères et revêtements
Partie
1
Nb partie
1
Application title
High Resolution X-Ray Diffraction Study of High-Density Polyethylene Subject to Controlled Stress and Temperature
Keyword
NSERC
Application summary
PexCor PEX pipes are manufactured and receive certification for certain service environments (ratings for*pressure, and temperature, proper installation procedure) to ensure adequate rated service life. If a pipe*occasionally fails prematurely PexCor needs to understand the root cause. Unfortunately one cannot install*pressure and temperature sensors in every system to ensure that the service parameters were not exceeded*during operation. X-ray crystallography may give an opportunity to see if there are any resolvable features in*stressed pipe to indicate high stress.*PexCor has the capability to subject PEX pipe to carefully controlled pressure and temperature stresses. A*series of pipe samples with a known stress history will be prepared and provided for the University of Guelph*x-ray diffraction lead by Prof Stefan Kycia. A thorough set of x-ray diffraction and scattering measurements*will be conducted on the samples to see if it is possible to track with the induced stress. X-ray diffraction is*sensitive to the preferred orientation, crystal quality, crystal structure, disorder, amorphous component, and*strain in the high density polyethylene tubing.*Solving this problem will require a thorough x-ray diffraction characterization of the samples. Measurements*will be conducted at the University of Guelph X-Ray Diffraction Laboratory as well as the Brockhouse Sector*at the Canadian Light Source.