Grant: Engage Plus Grants Program
University of Waterloo
$12,500.00
Fabrication of Polymer Hollow Microneedles for Transdermal Sample Extraction
FY 2017-18
Summary
For transdermal drug delivery, skin fluid and blood extraction, the conventional stainless steel needle causespain to the patients and is hard to be integrated with other medical devices at point-of-care-test fields. Onesolution to those limitations is micro-needle array because of its minimal invasive area/depth causing less painand ability to be integrated with other micro-devices. Moreover, no cases of infection by micro-needles havebeen reported so far. Such micro-needles can be solid or hollow with a length of 100-900 µm and an externaldiameter of not more than 300 µm. The supporting company ExVivo Labs is pioneering novel point-of-caremedical technologies for screening allergies. Its allergy test patches are based on extraction using micro-needlearray of disease indicating biomarkers, such as immunoglobulin-E (IgE), which mediates type I hypersensitivityreactions, known as allergies. In the previous funded Engage project, we aimed to fabricate hollow siliconmicro-needle array using MEMS microfabrication techniques, notably photolithography and deep siliconetching. The fabricated needles will be subsequently sharpened to under 10 micrometers for painless insertioninto skin. In the current Engage Plus project, we aim to fabricate polymer hollow micro-needle array that isadvantageous over silicon in certain aspects.
Program
Engage Plus Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
514392-2017
Name nom
Cui, Bo
Department département
Electrical & Computer Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
12500
Program id
EGP2
Program name en
Engage Plus Grants Program
Program name fr
Programme de subvention d'engagement partenarial Plus
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2519
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Microelectronics
Research subject fr
Microélectronique
Partie
1
Nb partie
1
Application title
Fabrication of Polymer Hollow Microneedles for Transdermal Sample Extraction
Keyword
NSERC
Application summary
For transdermal drug delivery, skin fluid and blood extraction, the conventional stainless steel needle causespain to the patients and is hard to be integrated with other medical devices at point-of-care-test fields. Onesolution to those limitations is micro-needle array because of its minimal invasive area/depth causing less painand ability to be integrated with other micro-devices. Moreover, no cases of infection by micro-needles havebeen reported so far. Such micro-needles can be solid or hollow with a length of 100-900 µm and an externaldiameter of not more than 300 µm. The supporting company ExVivo Labs is pioneering novel point-of-caremedical technologies for screening allergies. Its allergy test patches are based on extraction using micro-needlearray of disease indicating biomarkers, such as immunoglobulin-E (IgE), which mediates type I hypersensitivityreactions, known as allergies. In the previous funded Engage project, we aimed to fabricate hollow siliconmicro-needle array using MEMS microfabrication techniques, notably photolithography and deep siliconetching. The fabricated needles will be subsequently sharpened to under 10 micrometers for painless insertioninto skin. In the current Engage Plus project, we aim to fabricate polymer hollow micro-needle array that isadvantageous over silicon in certain aspects.