Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

École Polytechnique de Montréal

$25,000.00

Improvements and applications of optical coherence tomography for biomedical imaging

FY 2010-11

Summary
Optical Coherence Tomography (OCT) and especially Doppler OCT (DOCT) are new technologies that raise much interest and just begin to reveal their full potential. OCT provides depth-resolved three-dimensional and (quasi-)real-time imaging of living tissue and other semi-transparent samples in a non-invasive way using low-coherence interferometry. DOCT provides high resolution and high dynamic range measurements of fluid velocities in a variety of geometries relevant to microfluidics and vascular conditions such as stenoses and branching arteries. The proposed research program will capitalize on previous work done in this area at the Biophotonics Laboratory at Ecole Polytechnique. It will introduce several improvements in the existing system in terms of higher resolution (approaching 1 µm) and wider dynamic range (circa 80 dB), a faster response (a few images per second) and vectorial velocity maps of fluid flow thus opening the door to a) high resolution fluid dynamic studies in labs-on-a-chip by monitoring microflows in cell cultures and b) flow and wall shear stress studies in arterial phantoms, a topic of prime importance for the assessment of the effect of flow on plaque formation in atherosclerosis. Improvements will cover: a) more efficient hardware; b) faster data acquisition methods; c) better data processing approaches; d) display interfaces; e) multimodality; f) efficient and precise vectorial maps of velocities. Coupled with other imaging modalities (fluorescence, confocal, two-photon) on a single platform, Doppler OCT could become a truly powerful diagnostics tool with unprecedented resolution and functionality.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
6708-2009
Name nom
Maciejko, Romain
Department département
Génie physique
Organization id
64
Institution établissement
École Polytechnique de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2009
Award amount
25000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1079
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et de l'informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
2
Application title
Improvements and applications of optical coherence tomography for biomedical imaging
Keyword
NSERC
Application summary
Optical Coherence Tomography (OCT) and especially Doppler OCT (DOCT) are new technologies that raise much interest and just begin to reveal their full potential. OCT provides depth-resolved three-dimensional and (quasi-)real-time imaging of living tissue and other semi-transparent samples in a non-invasive way using low-coherence interferometry. DOCT provides high resolution and high dynamic range measurements of fluid velocities in a variety of geometries relevant to microfluidics and vascular conditions such as stenoses and branching arteries. The proposed research program will capitalize on previous work done in this area at the Biophotonics Laboratory at Ecole Polytechnique. It will introduce several improvements in the existing system in terms of higher resolution (approaching 1 µm) and wider dynamic range (circa 80 dB), a faster response (a few images per second) and vectorial velocity maps of fluid flow thus opening the door to a) high resolution fluid dynamic studies in labs-on-a-chip by monitoring microflows in cell cultures and b) flow and wall shear stress studies in arterial phantoms, a topic of prime importance for the assessment of the effect of flow on plaque formation in atherosclerosis. Improvements will cover: a) more efficient hardware; b) faster data acquisition methods; c) better data processing approaches; d) display interfaces; e) multimodality; f) efficient and precise vectorial maps of velocities. Coupled with other imaging modalities (fluorescence, confocal, two-photon) on a single platform, Doppler OCT could become a truly powerful diagnostics tool with unprecedented resolution and functionality.