Grant: Discovery Grants Program - Individual
McGill University
$19,000.00
Monte Carlo track structure applications in microdosimetry and radiation response
FY 2018-19
Summary
In radiation therapy ionizing radiation is used to cause irreparable damage to the DNA and inhibit cell cycling of the cancer cells. Particle tracks superimposed on models of DNA indicate that damage occurs in clusters. These clustered DNA damages are the signature DNA lesion induced by ionizing radiation. The biological response to radiation is quantified in terms of the relative biological effectiveness (RBE), defined as the ratio between the absorbed dose of a reference radiation and that of a test radiation for a given biological endpoint. Low energy brachytherapy sources, proton and ion beams are associated with high RBE values. Numerous simulations of initial DNA damage suggest that the frequency distributions for ionisation or energy imparted in volumes representative of DNA segments are useful for considering radiation quality and for modelling biological damage produced by ionising radiation. *Monte Carlo (MC) method is an accurate and rigorous tool to simulate radiation transport and score energy deposition in heterogeneous systems such as the human body. Track structure codes are a specific class of MC transport codes that can generate in detail the spatial pattern of energy deposit sites due to the event-by-event simulation of particle interactions. *The aim of this proposal is to increase the knowledge about the mechanisms behind the varying RBE for different combinations of radiation and tumour cell types and normal tissues by studying in detail the ionization and excitation patterns caused by different radiation qualities, in order to gain the same confidence and control for low energy photon emitting brachytherapy sources, proton and particle therapy as for conventional radiation therapy. The analysis will be combined with observed radiation responses for different cell lines and radiation qualities, and an evidence based link between well-known and controlled physical beam properties and clinically observed radiation response parameterizations will be established. With such models in treatment planning, the clinicians can better choose and optimize the type of radiation and dose distribution for each patient. *Aim A: Use methods developed in an earlier study to investigate if the microdosimetric variation of energy imparted per cell, due to the different size of the cells and their nuclei within a tissue sample, have an impact on experimentally determined cell survival curves and tumour control probability. *Aim B: Develop and use track structure codes to search for a relationship between frequency distribution of order of clusters of energy deposit sites, as a descriptor of radiation impact, and RBE for cell survival for various radiation qualities. A method for predicting RBE values for low energy photons, protons and other ions on the basis of dose-response data obtained from photons will be developed and included in radiation therapy treatment plans. *
Program
Discovery Grants Program - Individual
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2015-04984
Name nom
Enger, Shirin
Department département
Medical Physics Unit
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2015
Award amount
19000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
4
Nb partie
5
Application title
Monte Carlo track structure applications in microdosimetry and radiation response
Keyword
NSERC
Application summary
In radiation therapy ionizing radiation is used to cause irreparable damage to the DNA and inhibit cell cycling of the cancer cells. Particle tracks superimposed on models of DNA indicate that damage occurs in clusters. These clustered DNA damages are the signature DNA lesion induced by ionizing radiation. The biological response to radiation is quantified in terms of the relative biological effectiveness (RBE), defined as the ratio between the absorbed dose of a reference radiation and that of a test radiation for a given biological endpoint. Low energy brachytherapy sources, proton and ion beams are associated with high RBE values. Numerous simulations of initial DNA damage suggest that the frequency distributions for ionisation or energy imparted in volumes representative of DNA segments are useful for considering radiation quality and for modelling biological damage produced by ionising radiation. *Monte Carlo (MC) method is an accurate and rigorous tool to simulate radiation transport and score energy deposition in heterogeneous systems such as the human body. Track structure codes are a specific class of MC transport codes that can generate in detail the spatial pattern of energy deposit sites due to the event-by-event simulation of particle interactions. *The aim of this proposal is to increase the knowledge about the mechanisms behind the varying RBE for different combinations of radiation and tumour cell types and normal tissues by studying in detail the ionization and excitation patterns caused by different radiation qualities, in order to gain the same confidence and control for low energy photon emitting brachytherapy sources, proton and particle therapy as for conventional radiation therapy. The analysis will be combined with observed radiation responses for different cell lines and radiation qualities, and an evidence based link between well-known and controlled physical beam properties and clinically observed radiation response parameterizations will be established. With such models in treatment planning, the clinicians can better choose and optimize the type of radiation and dose distribution for each patient. *Aim A: Use methods developed in an earlier study to investigate if the microdosimetric variation of energy imparted per cell, due to the different size of the cells and their nuclei within a tissue sample, have an impact on experimentally determined cell survival curves and tumour control probability. *Aim B: Develop and use track structure codes to search for a relationship between frequency distribution of order of clusters of energy deposit sites, as a descriptor of radiation impact, and RBE for cell survival for various radiation qualities. A method for predicting RBE values for low energy photons, protons and other ions on the basis of dose-response data obtained from photons will be developed and included in radiation therapy treatment plans. *