Grant: Discovery Grants Program - Individual
University of Saskatchewan
$31,000.00
Dynamic Enhancement and Protection of Power Systems with Large Penetration of Renewable Energy
FY 2018-19
Summary
*The need to address global climate change, a worldwide environmental phenomenon that will affect everyone on earth, is the most public driving force for the utilization of renewable energy. Grid integration of large capacity of renewable energy sources and the use of large capacity of electrical energy storage is now a reality. These types of grid require, however, new approaches for system dynamic enhancement and protection. The research work that the applicant is planned to undertake will advance upon two major thrusts.*Thrust 1: Dynamic Enhancement of Power Systems with Large Capacity of Renewable Energies*This thrust will explore the potential use of supplemental controls of Doubly-Fed Induction Generator (DFIG) and Full-Scale Frequency Converter (FFC) wind farms for the mitigation of subsynchronous resonance (SSR: the interaction between series capacitor compensated transmission systems and turbine-generator shaft system) and subsynchronous interaction (SSI: the interaction between series capacitor compensated transmission systems and DFIG-based wind farms).*As most large wind farms employ DFIG and FFC wind turbines, their voltage-sourced converter-based back-to-backs (BtBs) offer decoupled control of the real and reactive power. The use of these control capabilities have been recently proposed for damping power swings, inter-area oscillations and SSI. In integrated power systems incorporating series capacitor compensated transmission lines and high penetration of wind energy conversion systems, SSR and SSI could exist simultaneously during some system contingences. Thus, alleviating SSR and SSI has been an attractive area of research and development targeting at developing practical and effective countermeasures.*Thrust 2: Protection of Power Systems with Large Capacity of Renewable Energies*The results of the investigations on the impact of midpoint STATCOM on the performance of generator phase backup protection and generator loss of excitation protection have revealed that the midpoint STATCOM has an adverse effect on such protections which can be in the form of underreach, overreach or a time delay.*As the Grid-Side Converters of DFIG and FFC wind turbines appear to the generators as STATCOMs, high penetration of these types of renewable energy conversion systems is expected to have an adverse effect on the performance of generator distance relays.*A major investigation in this thrust is exploring the impact of high penetration of wind energy conversion systems on generator distance phase backup protection and loss of excitation protection in order to identify the important issues that protection engineers need to consider when designing and setting the protection system. In addition, practical and feasible solutions to mitigate the adverse impact of renewable energy conversion systems on generator and transmission line distance protection will be explored.*
Program
Discovery Grants Program - Individual
Recipient
Location
Saskatchewan, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2016-03727
Name nom
Faried, Sherif
Department département
Electrical & Computer Engineering
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2016
Award amount
31000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
3
Nb partie
5
Application title
Dynamic Enhancement and Protection of Power Systems with Large Penetration of Renewable Energy
Keyword
NSERC
Application summary
*The need to address global climate change, a worldwide environmental phenomenon that will affect everyone on earth, is the most public driving force for the utilization of renewable energy. Grid integration of large capacity of renewable energy sources and the use of large capacity of electrical energy storage is now a reality. These types of grid require, however, new approaches for system dynamic enhancement and protection. The research work that the applicant is planned to undertake will advance upon two major thrusts.*Thrust 1: Dynamic Enhancement of Power Systems with Large Capacity of Renewable Energies*This thrust will explore the potential use of supplemental controls of Doubly-Fed Induction Generator (DFIG) and Full-Scale Frequency Converter (FFC) wind farms for the mitigation of subsynchronous resonance (SSR: the interaction between series capacitor compensated transmission systems and turbine-generator shaft system) and subsynchronous interaction (SSI: the interaction between series capacitor compensated transmission systems and DFIG-based wind farms).*As most large wind farms employ DFIG and FFC wind turbines, their voltage-sourced converter-based back-to-backs (BtBs) offer decoupled control of the real and reactive power. The use of these control capabilities have been recently proposed for damping power swings, inter-area oscillations and SSI. In integrated power systems incorporating series capacitor compensated transmission lines and high penetration of wind energy conversion systems, SSR and SSI could exist simultaneously during some system contingences. Thus, alleviating SSR and SSI has been an attractive area of research and development targeting at developing practical and effective countermeasures.*Thrust 2: Protection of Power Systems with Large Capacity of Renewable Energies*The results of the investigations on the impact of midpoint STATCOM on the performance of generator phase backup protection and generator loss of excitation protection have revealed that the midpoint STATCOM has an adverse effect on such protections which can be in the form of underreach, overreach or a time delay.*As the Grid-Side Converters of DFIG and FFC wind turbines appear to the generators as STATCOMs, high penetration of these types of renewable energy conversion systems is expected to have an adverse effect on the performance of generator distance relays.*A major investigation in this thrust is exploring the impact of high penetration of wind energy conversion systems on generator distance phase backup protection and loss of excitation protection in order to identify the important issues that protection engineers need to consider when designing and setting the protection system. In addition, practical and feasible solutions to mitigate the adverse impact of renewable energy conversion systems on generator and transmission line distance protection will be explored.*