Grant: Alliance Grants
University of Guelph
$55,000.00
Machine learning-based quality control of canine thoracic radiographs
FY 2021-22
Summary
In animal hospitals and veterinary clinics, radiographs are taken by veterinary technicians and are often sent for a teleradiology consult by radiologists who are not present on-site. Turn around times for these studies range from 1 hour (STAT cases) to 2-3 days (non-emergency cases). Low-quality or poorly positioned radiographs may cause erroneous diagnosis and, in severe cases, may be classified as nondiagnostic by the radiologist. Therefore, quality control of the radiographs plays an important role in providing a reliable interpretation and convenient service to the patient. The training of personnel in proper positioning as well as modern x-ray units with wide exposure latitude and dynamic range help to reduce technical errors and increase quality. However, radiologists still receive radiographs with inappropriately collimated anatomy and inadequate positioning. As a result, there are a considerable number of canine thorax radiographs that render nondiagnostic or are limited in their diagnostic value. This increases the cost to veterinary clinics and clients, as well as increases radiation exposure to patients and personnel. Therefore, the importance of good image quality in radiographic studies to avoid the misleading or erroneous diagnosis, to reduce overall costs and to reduce radiation exposure, cannot be overstated. We propose a machine learning algorithm that analyzes the canine lateral thorax radiograph and evaluates its appropriateness before it is sent to the radiologist for diagnosis. We also aim to develop a sensor system that helps position the patient and reduce the room for technical error. The proposed work will benefit Canadian veterinarians as well as pet owners by 1) reducing the costs associated with repeating sedation and radiograph acquisition; 2) reducing the financial burden on the client to return to the veterinary clinic; 3) reducing technical staff availability; 3) eliminating roughly $2.5 variable cost per radiograph retake; and 4) eliminating the $50-100 telemedicine consultation fee per radiographic study if resubmitted for evaluation.
Program
Alliance Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
560314-2020
Name nom
Komeili, Amin
Department département
Engineering and Physical Sciences, College of
Organization id
24
Institution établissement
University of Guelph
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2020
Award amount
55000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
102
Area of application group en
Agriculture and primary food production
Area of application group fr
Agriculture et produits alimentaires primaires
Area of application en
Animal management (animal diseases, breeding)
Area of application fr
Gestion des animaux (maladies animales, reproduction)
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:2
Partie
1
Nb partie
2
Application title
Machine learning-based quality control of canine thoracic radiographs
Keyword
NSERC
Application summary
In animal hospitals and veterinary clinics, radiographs are taken by veterinary technicians and are often sent for a teleradiology consult by radiologists who are not present on-site. Turn around times for these studies range from 1 hour (STAT cases) to 2-3 days (non-emergency cases). Low-quality or poorly positioned radiographs may cause erroneous diagnosis and, in severe cases, may be classified as nondiagnostic by the radiologist. Therefore, quality control of the radiographs plays an important role in providing a reliable interpretation and convenient service to the patient. The training of personnel in proper positioning as well as modern x-ray units with wide exposure latitude and dynamic range help to reduce technical errors and increase quality. However, radiologists still receive radiographs with inappropriately collimated anatomy and inadequate positioning. As a result, there are a considerable number of canine thorax radiographs that render nondiagnostic or are limited in their diagnostic value. This increases the cost to veterinary clinics and clients, as well as increases radiation exposure to patients and personnel. Therefore, the importance of good image quality in radiographic studies to avoid the misleading or erroneous diagnosis, to reduce overall costs and to reduce radiation exposure, cannot be overstated. We propose a machine learning algorithm that analyzes the canine lateral thorax radiograph and evaluates its appropriateness before it is sent to the radiologist for diagnosis. We also aim to develop a sensor system that helps position the patient and reduce the room for technical error. The proposed work will benefit Canadian veterinarians as well as pet owners by 1) reducing the costs associated with repeating sedation and radiograph acquisition; 2) reducing the financial burden on the client to return to the veterinary clinic; 3) reducing technical staff availability; 3) eliminating roughly $2.5 variable cost per radiograph retake; and 4) eliminating the $50-100 telemedicine consultation fee per radiographic study if resubmitted for evaluation.