Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Carleton University

$21,000.00

Fire Performance of HSS Steel Connections

FY 2017-18

Summary
Background: Fires can cause elevated temperature that can have adverse impact on the building elements andsystems. Steel connections are vital and essential components of any steel structure. Observations from firesconfirm that connections have considerable effect on the survival time of structural members due to their rolein distributing forces. Hollow Steel Sections HSS are known to absorb heat energy at higher rates than thicksteel sections, causing earlier yielding to occur. In a fire event, restrained steel beams can heat up quickly andcause lateral thrust on supporting columns. It is likely that columns fail because of this thrust, and notnecessarily because of the elevated temperatures.Objectives: The proposed research aims to examine and evaluate, under fire conditions, the performance ofexisting HSS-to-HSS extended end-plate moment connections and work towards introducing a new connectioncapable of absorbing or redirecting the lateral thrust.Scientific approach: Using medium- and full-scale experiments, the performance of current and proposedHSS-to-HSS extended end-plate moment connections in fire conditions will be assessed. The proposedresearch focuses on how to utilize the catenary action in fire in order to improve the fire performance ofrestrained steel beams. ABAQUS finite element model will be used to analyze the couple effect of thermal andstructural performance. Both design fires (for commercial and industrial type occupancies) as well as standardtime-temperature profiles will be applied to the connections using a newly constructed fire facility at CarletonUniversity's.The research is expected to advance the understanding of fire behaviour of the commonly used steelconnections (not isolated connections), and propose an advanced connection that can enhance the stability inthe event of fire. The results will be used to produce a fire resistance design method of beam-to-columnconnections.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
371673-2013
Name nom
Zalok, Ehab
Department département
Civil and Environmental Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2013
Award amount
21000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
5
Nb partie
5
Application title
Fire Performance of HSS Steel Connections
Keyword
NSERC
Application summary
Background: Fires can cause elevated temperature that can have adverse impact on the building elements andsystems. Steel connections are vital and essential components of any steel structure. Observations from firesconfirm that connections have considerable effect on the survival time of structural members due to their rolein distributing forces. Hollow Steel Sections HSS are known to absorb heat energy at higher rates than thicksteel sections, causing earlier yielding to occur. In a fire event, restrained steel beams can heat up quickly andcause lateral thrust on supporting columns. It is likely that columns fail because of this thrust, and notnecessarily because of the elevated temperatures.Objectives: The proposed research aims to examine and evaluate, under fire conditions, the performance ofexisting HSS-to-HSS extended end-plate moment connections and work towards introducing a new connectioncapable of absorbing or redirecting the lateral thrust.Scientific approach: Using medium- and full-scale experiments, the performance of current and proposedHSS-to-HSS extended end-plate moment connections in fire conditions will be assessed. The proposedresearch focuses on how to utilize the catenary action in fire in order to improve the fire performance ofrestrained steel beams. ABAQUS finite element model will be used to analyze the couple effect of thermal andstructural performance. Both design fires (for commercial and industrial type occupancies) as well as standardtime-temperature profiles will be applied to the connections using a newly constructed fire facility at CarletonUniversity's.The research is expected to advance the understanding of fire behaviour of the commonly used steelconnections (not isolated connections), and propose an advanced connection that can enhance the stability inthe event of fire. The results will be used to produce a fire resistance design method of beam-to-columnconnections.