Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Simon Fraser University

$24,997.00

Deformable fluidic actuator

FY 2009-10

Summary
We focus on the development of a deformable laryngoscope, which has different clinical applications, including first use intubations, bariatric surgery, and cervical spine immobilization. Currently, laryngoscopes have a fixed geometry and a rigid structure. Their main limitation is that they cannot adapt to different shapes of patients' mouths. In addition, they do not provide any force feedback to the paramedics who use it. Being rigid, they can also damage a patient's oral cavity if handled improperly. We have developed a novel, highly deformable fluidic actuator (DFA) capable of displaying large deformations. Its design is based on a micro-channel embedded on a polymeric substrate, which is fixed to an inextensible, but bendable, backbone. The DFA would be suitable as a substitute for the final segment of laryngoscopes and it could be used to lift the tongue to clear a patient's airway. The DFA can be manufactured by using biocompatible and inexpensive polymers and thus could be suitable for commercial biomedical applications. The proposed research has the potential to provide substantial benefits for Canada as it has numerous applications for medicine including: (1) intubation for mechanical ventilation; (2) intubation for anesthesia administration; (3) inspection of throat pain; (4) evaluation issues in throat swallowing; (5) analysis of obstruction masses in the airway; and (6) inspection of vocal cords.
Program
Engage Grants Program
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
395155-2009
Name nom
Menon, Carlo
Department département
Engineering Science, School of
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2009
Award amount
24997
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1700
Research subject group en
Design and manufacturing
Research subject group fr
Conception et fabrication
Research subject en
Design and manufacturing
Research subject fr
Conception et fabrication
Partie
1
Nb partie
1
Application title
Deformable fluidic actuator
Keyword
NA
Application summary
We focus on the development of a deformable laryngoscope, which has different clinical applications, including first use intubations, bariatric surgery, and cervical spine immobilization. Currently, laryngoscopes have a fixed geometry and a rigid structure. Their main limitation is that they cannot adapt to different shapes of patients' mouths. In addition, they do not provide any force feedback to the paramedics who use it. Being rigid, they can also damage a patient's oral cavity if handled improperly. We have developed a novel, highly deformable fluidic actuator (DFA) capable of displaying large deformations. Its design is based on a micro-channel embedded on a polymeric substrate, which is fixed to an inextensible, but bendable, backbone. The DFA would be suitable as a substitute for the final segment of laryngoscopes and it could be used to lift the tongue to clear a patient's airway. The DFA can be manufactured by using biocompatible and inexpensive polymers and thus could be suitable for commercial biomedical applications. The proposed research has the potential to provide substantial benefits for Canada as it has numerous applications for medicine including: (1) intubation for mechanical ventilation; (2) intubation for anesthesia administration; (3) inspection of throat pain; (4) evaluation issues in throat swallowing; (5) analysis of obstruction masses in the airway; and (6) inspection of vocal cords.