Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Queen's University

$44,000.00

Vibration and noise reduction in MRI scanners

FY 2007-08

Summary
Magnetic Resonance Imaging (MRI) is an important technique in diagnostic medicine and medical research. High-field, high-speed MRI scanners generate detailed images of the internal structure of biological samples and human subjects. While MRI is an effective tool in medicine, the vibration and noise generated during the imaging process presents significant problems for patients (heightened anxiety), health care workers (permanent hearing impairment), and medical research and diagnostic personnel (limited image resolution). This research proposes to achieve significant improvements in image quality and noise reduction by focusing on the development of technology that can be designed into new machines or used seamlessly with existing MRI scanners. Active vibration and noise control systems for use inside the MRI environment will be developed. Enhancement and validation of computational (FEA based) and analytical models of the vibration (using an extension of the thin-walled cylinder model) and noise generating and transmission processes (using a Green's function model and a baffled finite cylinder model) will be carried out. Gradient coil design optimization to minimize vibration while still satisfying all other constraints will be investigated and validated through testing of prototype coils. The new technology to be developed will greatly improve the quality of the patient care when using MRI. At the same time MR image quality will be improved. As a result, the quality of the research conducted with MRI scanners can be expected to improve in step. The development of highly optimized MRI sub-system components with reduced vibration and noise production will accelerate research involving microscopic MRI with cellular and molecular sensitivity. The research systems developed will serve as prototypes to test the feasibility of new technology. These new systems will also push the performance of the MRI sub-systems far beyond what is currently done clinically, and the lessons learned from this investigation will guide the future development of clinical MRI systems.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
203023-2006
Name nom
Mechefske, Christopher
Department département
Mechanical and Materials Engineering
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
44000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
13
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2104
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Vibrations
Research subject fr
Vibrations
Partie
2
Nb partie
5
Application title
Vibration and noise reduction in MRI scanners
Keyword
NA
Application summary
Magnetic Resonance Imaging (MRI) is an important technique in diagnostic medicine and medical research. High-field, high-speed MRI scanners generate detailed images of the internal structure of biological samples and human subjects. While MRI is an effective tool in medicine, the vibration and noise generated during the imaging process presents significant problems for patients (heightened anxiety), health care workers (permanent hearing impairment), and medical research and diagnostic personnel (limited image resolution). This research proposes to achieve significant improvements in image quality and noise reduction by focusing on the development of technology that can be designed into new machines or used seamlessly with existing MRI scanners. Active vibration and noise control systems for use inside the MRI environment will be developed. Enhancement and validation of computational (FEA based) and analytical models of the vibration (using an extension of the thin-walled cylinder model) and noise generating and transmission processes (using a Green's function model and a baffled finite cylinder model) will be carried out. Gradient coil design optimization to minimize vibration while still satisfying all other constraints will be investigated and validated through testing of prototype coils. The new technology to be developed will greatly improve the quality of the patient care when using MRI. At the same time MR image quality will be improved. As a result, the quality of the research conducted with MRI scanners can be expected to improve in step. The development of highly optimized MRI sub-system components with reduced vibration and noise production will accelerate research involving microscopic MRI with cellular and molecular sensitivity. The research systems developed will serve as prototypes to test the feasibility of new technology. These new systems will also push the performance of the MRI sub-systems far beyond what is currently done clinically, and the lessons learned from this investigation will guide the future development of clinical MRI systems.