Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Alberta

$34,000.00

Technologies for large-channel-count MRI array detectors

FY 2011-12

Summary
This research program aims to develop technical solutions that will improve the quality and acquisition speed of magnetic resonance imaging (MRI). One way to achieve these improvements is to make the large magnets on which MRI is based much stronger. However this solution comes at great financial cost. This research program aims to take advantage of recent improvements in data acquisition systems that have allowed MRI scanners to receive using greater numbers of multiple antenna-like sensors (""array coils"") than ever before (think of megapixels in a digital camera). Array coils with large numbers of elements make optimal use of existing MRI field strengths and offer improvements in image quality and acquisition speed over those from arrays with fewer elements. However, building such large arrays is a challenging task due to the need to connect individual cables to each of the array's loop-shaped elements. The additional cables further contribute to ""crosstalk"" between the loops (think of trying to listen to one conversation from a distance in a room crowded with people). As the loop dimensions shrink the amplifiers connected to the loops are no longer ideal as current design methods assume. The objective of this research program is to optimize the performance of large arrays for MRI and take full advantage of existing MRI field strengths by improving the design methods and using fiber-optics to eliminate the problems caused by the increasing number of cables.
Program
Discovery Grants Program - Individual
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
372040-2009
Name nom
DeZanche, Nicola
Department département
Oncology
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2009
Award amount
34000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1079
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et de l'informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
3
Nb partie
5
Application title
Technologies for large-channel-count MRI array detectors
Keyword
NSERC
Application summary
This research program aims to develop technical solutions that will improve the quality and acquisition speed of magnetic resonance imaging (MRI). One way to achieve these improvements is to make the large magnets on which MRI is based much stronger. However this solution comes at great financial cost. This research program aims to take advantage of recent improvements in data acquisition systems that have allowed MRI scanners to receive using greater numbers of multiple antenna-like sensors (""array coils"") than ever before (think of megapixels in a digital camera). Array coils with large numbers of elements make optimal use of existing MRI field strengths and offer improvements in image quality and acquisition speed over those from arrays with fewer elements. However, building such large arrays is a challenging task due to the need to connect individual cables to each of the array's loop-shaped elements. The additional cables further contribute to ""crosstalk"" between the loops (think of trying to listen to one conversation from a distance in a room crowded with people). As the loop dimensions shrink the amplifiers connected to the loops are no longer ideal as current design methods assume. The objective of this research program is to optimize the performance of large arrays for MRI and take full advantage of existing MRI field strengths by improving the design methods and using fiber-optics to eliminate the problems caused by the increasing number of cables.