Grant: Collaborative Research and Development Grants
University of Prince Edward Island
$33,250.00
Innovative system and process for optimization of wastewater treatment
FY 2019-20
Summary
Charlottetown Pollution Control Plant (CPCP) is transforming into the Resource Recovery Facility. The goal is to create integrated sustainable systems to address energy needs and produce valuable products with the long-term financial, environmental and social benefits. CPCP treats approximately 7 million cubic meters of wastewater annually producing roughly 3700 tonnes of bio-solids. The wastewater treatment plant consists of primary and secondary treatment; the sludge is anaerobically digested for producing biogas and class-A biosolids. Wastewater treatment is an energy intensive process. The consumption is mainly attributed to the pumps and air blowers for moving wastewater and air to the aeration tanks, respectively. Air blowers account for 70% of the total electricity consumption in wastewater treatment plants. The supply of air promotes microbial growth, which feeds on organic matter. The process produces a flock, which settles to the bottom of the tank. The overall objective of the proposed research is to develop a sustainable system and process for improving the efficiency of the municipal wastewater treatment in terms of energy use and value recovery. The proposed research is divided into the following objectives: a) Develop robust, sensitive and consistent real-time in-line bacteria-based BOD biosensors; b) Characterize the impacts of using a separation column and an array of single semi-specific bacteria strain on the specificity of current bacteria-based biosensors; c) Identify the impact of biochar type, size and loading on the performance of the aeration tank through characterizing the impact of biochar on the settleability of sludge, air requirement, and treatment; d) Identify the impact of biochar type, size and loading on the performance of anaerobic digestion through characterizing the impact on rate of gas production, total gas yield and composition, and the quality of biosolids. The outcomes of the proposed research will support CPCP initiatives for reducing their carbon footprint and meeting their sustainability objectives.
Program
Collaborative Research and Development Grants
Recipient
Location
Prince Edward Island, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
543932-2019
Name nom
Acharya, Bishnu
Department département
Sustainable Design Engineering, School of
Organization id
88
Institution établissement
University of Prince Edward Island
Province en
Prince Edward Island
Province fr
Île-du-Prince-Édouard
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
33250
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
400
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Environment
Area of application fr
Environnement
Research subject code
1502
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Waste water treatment
Research subject fr
Traitement des eaux usées
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Innovative system and process for optimization of wastewater treatment
Keyword
NSERC
Application summary
Charlottetown Pollution Control Plant (CPCP) is transforming into the Resource Recovery Facility. The goal is to create integrated sustainable systems to address energy needs and produce valuable products with the long-term financial, environmental and social benefits. CPCP treats approximately 7 million cubic meters of wastewater annually producing roughly 3700 tonnes of bio-solids. The wastewater treatment plant consists of primary and secondary treatment; the sludge is anaerobically digested for producing biogas and class-A biosolids. Wastewater treatment is an energy intensive process. The consumption is mainly attributed to the pumps and air blowers for moving wastewater and air to the aeration tanks, respectively. Air blowers account for 70% of the total electricity consumption in wastewater treatment plants. The supply of air promotes microbial growth, which feeds on organic matter. The process produces a flock, which settles to the bottom of the tank. The overall objective of the proposed research is to develop a sustainable system and process for improving the efficiency of the municipal wastewater treatment in terms of energy use and value recovery. The proposed research is divided into the following objectives: a) Develop robust, sensitive and consistent real-time in-line bacteria-based BOD biosensors; b) Characterize the impacts of using a separation column and an array of single semi-specific bacteria strain on the specificity of current bacteria-based biosensors; c) Identify the impact of biochar type, size and loading on the performance of the aeration tank through characterizing the impact of biochar on the settleability of sludge, air requirement, and treatment; d) Identify the impact of biochar type, size and loading on the performance of anaerobic digestion through characterizing the impact on rate of gas production, total gas yield and composition, and the quality of biosolids. The outcomes of the proposed research will support CPCP initiatives for reducing their carbon footprint and meeting their sustainability objectives.