Grant: Engage Grants Program
University of British Columbia
$25,000.00
Performance evaluation of post-tensioned steel bridge pier using finite element analysis
FY 2017-18
Summary
More than 40% of Canadian civil infrastructure has passed its service life, and the municipal infrastructuredeficit has grown to $141B (CIRC 2016). If immediate measures are not taken to revamp the infrastructure, thecost of replacement may increase manifold. Such deficient infrastructure also poses a serious threat to thepublic during disasters like earthquakes. A recent study conducted by the Insurance Bureau of Canadaestimated the overall loss after a 9.0-magnitude earthquake in British Columbia at almost $75B (IBC 2013),which clearly reflects the vulnerability of Canadian civil infrastructure. In order to avoid such scenarios inCanada, and in other earthquake prone regions across the world, it is imperative to take immediate measures.The proposed research will introduce prefabricated post-tensioned steel bridge pier that will not only enablestructures to be built faster but also help structures self-center after major earthquakes. Such structures will beimmediately serviceable requiring no major repair works.Performance-based design is becoming a standard practice for seismic design and evaluation of structures inorder to achieve a reliable and satisfactory level of performance. However, there has been no study on theseismic performance of such self-centering steel bridge piers. This research will help develop properunderstanding and knowledge about the behavior of such bridges, which will eventually help us develop theperformance-based design guideline for such bridges. This study will assist engineers in examining theinteraction among different components of the bridge under lateral loads, and evaluate its limit states, anddetermine adequate section sizes and connection details and provide design implications. Finite elementmethod (FEM) will be implemented in this study where the models of self-centering bridge piers will begenerated in ANSYS FEM environment. Extensive FE analysis will be performed to determine the effect ofdifferent parameters including the steel strength, dimensions, amount of post-tensioning force and energydissipator characteristics on its behavior, and the preliminary design requirements.
Program
Engage Grants Program
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
514442-2017
Name nom
Alam, Shahria
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1107
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Earthquake engineering
Research subject fr
Génie parasismique
Partie
1
Nb partie
1
Application title
Performance evaluation of post-tensioned steel bridge pier using finite element analysis
Keyword
NSERC
Application summary
More than 40% of Canadian civil infrastructure has passed its service life, and the municipal infrastructuredeficit has grown to $141B (CIRC 2016). If immediate measures are not taken to revamp the infrastructure, thecost of replacement may increase manifold. Such deficient infrastructure also poses a serious threat to thepublic during disasters like earthquakes. A recent study conducted by the Insurance Bureau of Canadaestimated the overall loss after a 9.0-magnitude earthquake in British Columbia at almost $75B (IBC 2013),which clearly reflects the vulnerability of Canadian civil infrastructure. In order to avoid such scenarios inCanada, and in other earthquake prone regions across the world, it is imperative to take immediate measures.The proposed research will introduce prefabricated post-tensioned steel bridge pier that will not only enablestructures to be built faster but also help structures self-center after major earthquakes. Such structures will beimmediately serviceable requiring no major repair works.Performance-based design is becoming a standard practice for seismic design and evaluation of structures inorder to achieve a reliable and satisfactory level of performance. However, there has been no study on theseismic performance of such self-centering steel bridge piers. This research will help develop properunderstanding and knowledge about the behavior of such bridges, which will eventually help us develop theperformance-based design guideline for such bridges. This study will assist engineers in examining theinteraction among different components of the bridge under lateral loads, and evaluate its limit states, anddetermine adequate section sizes and connection details and provide design implications. Finite elementmethod (FEM) will be implemented in this study where the models of self-centering bridge piers will begenerated in ANSYS FEM environment. Extensive FE analysis will be performed to determine the effect ofdifferent parameters including the steel strength, dimensions, amount of post-tensioning force and energydissipator characteristics on its behavior, and the preliminary design requirements.