Grant: Discovery Grants Program - Individual
Queen's University
$48,000.00
A hybrid piezoelectric/silicon array for ultrasound intravascular/intracardiac imaging
FY 2009-10
Summary
High frequency ultrasound is a relatively new field in medical imaging. Compared with conventional ultrasound systems operating at 3.5 MHz, a high frequency system operating at 50 MHz could resolve structures approximately 15 times smaller. A valuable application of high frequency imaging is catheter based intravascular imaging for assisting in the selection and evaluation of the therapeutic procedures used to re-establish the flow in occluded arteries. High frequency ultrasound systems currently use single-element transducers that are either unfocused or geometrically shaped to focus the ultrasound. Although this approach simplifies the development of the transducer and system electronics, the fixed geometry of the transducer introduces a compromise between image resolution and the depth over which the image can be focused. Conventional scanners operating in the 2-10 MHz frequency range avoid this problem by using a linear transducer array with between 100-200 individual transducer elements. By appropriately delaying the signals applied to and received from the array elements using an ultrasound beamformer, the ultrasound beam can be scanned and focused throughout the image plane. Unfortunately, fabricating transducer arrays suitable for high frequency imaging is challenging due to the small size of the array elements. It is even more challenging to fabricate a high frequency array suitable for a catheter based imaging system since the outer diameter of the catheter ultimately limits how many cables can be used to connect to the array elements. The goal of the research described in this proposal is to design and fabricate a miniature (1-2 mm diameter) high frequency (50 MHz) electronically 'scannable' annular array for intravascular imaging. The array will be developed based on a hybrid transducer structure incorporating a piezoelectric substrate and a silicon substrate in the same device. The resulting array will provide electronic focusing and steering of the ultrasound beam while using only 1/10th of the cables required by a more conventional design.
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
216924-2009
Name nom
Lockwood, Geoffrey
Department département
Physics
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2009
Award amount
48000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1079
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et de l'informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2524
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Ultrasonic/ferroelectric devices and applications
Research subject fr
Applications et dispositifs ultrasoniques et ferroélectriques
Partie
1
Nb partie
5
Application title
A hybrid piezoelectric/silicon array for ultrasound intravascular/intracardiac imaging
Keyword
NA
Application summary
High frequency ultrasound is a relatively new field in medical imaging. Compared with conventional ultrasound systems operating at 3.5 MHz, a high frequency system operating at 50 MHz could resolve structures approximately 15 times smaller. A valuable application of high frequency imaging is catheter based intravascular imaging for assisting in the selection and evaluation of the therapeutic procedures used to re-establish the flow in occluded arteries. High frequency ultrasound systems currently use single-element transducers that are either unfocused or geometrically shaped to focus the ultrasound. Although this approach simplifies the development of the transducer and system electronics, the fixed geometry of the transducer introduces a compromise between image resolution and the depth over which the image can be focused. Conventional scanners operating in the 2-10 MHz frequency range avoid this problem by using a linear transducer array with between 100-200 individual transducer elements. By appropriately delaying the signals applied to and received from the array elements using an ultrasound beamformer, the ultrasound beam can be scanned and focused throughout the image plane. Unfortunately, fabricating transducer arrays suitable for high frequency imaging is challenging due to the small size of the array elements. It is even more challenging to fabricate a high frequency array suitable for a catheter based imaging system since the outer diameter of the catheter ultimately limits how many cables can be used to connect to the array elements. The goal of the research described in this proposal is to design and fabricate a miniature (1-2 mm diameter) high frequency (50 MHz) electronically 'scannable' annular array for intravascular imaging. The array will be developed based on a hybrid transducer structure incorporating a piezoelectric substrate and a silicon substrate in the same device. The resulting array will provide electronic focusing and steering of the ultrasound beam while using only 1/10th of the cables required by a more conventional design.