Grant: Engage Grants Program
University of Calgary
$25,000.00
Silica removal from SAGD boiler blowdown by electrocoagulation
FY 2017-18
Summary
Heavy oil production of steam assisted gravity drainage (SAGD) is the largest in-situ production process in theCanadian oil-sands. This production process generates large quantities of produced water, typically 3 to 4 timesthe volume of oil, which must be treated and recycled to ensure that the process is viable and to meet regulatoryrequirements. The produced water must be treated before being fed to the steam generator (boiler) for injectioninto the reservoir as steam. To avoid fouling of the boilers, the water is usually treated by a process of warm orhot lime softening to remove hardness and silica which can scale the boilers. This process is high cost andgenerates significant volumes of sludge. An alternative process, so-called zero lime softening is beingdeveloped by the industry partner, Eco-Tech, which is lower cost and more environmentally freindly.Eco-Tech have shown that if the produced water is treated to remove hardness, the silica can be at a relativelyhigh concentration (>200 mg/L), without causing significant scaling of the boilers. However, the concentratestream from the boilers contains greater than 1200 mg/L silica, and must be treated prior to recycle or disposal.Conventional chemical processes (acidification) lead to a silica gel sludge which is difficult o separate from thewater. Electrocoagulation (EC), has been identified as a potential treatment process for the blowdownconcentrate. In previous work, we have been found that EC can effectively remove silica from SAGD producedwater. This project will investigate EC for the treatment of blowdown concentrate generated by the zero-limesoftening process. The treatment performance and filterability of the sludge will be investigated as a function ofthe operating conditions and design of the EC system.
Program
Engage Grants Program
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
515024-2017
Name nom
Roberts, Edward
Department département
Chemical and Petroleum Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
300
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy resources (including production, exploration, processing, distribution and use)
Area of application fr
Ressources d'énergie (production, exploration, traitement, distribution et utilisation de l'énergie)
Research subject code
1806
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Separation processes
Research subject fr
Procédés de séparation
Partie
1
Nb partie
1
Application title
Silica removal from SAGD boiler blowdown by electrocoagulation
Keyword
NSERC
Application summary
Heavy oil production of steam assisted gravity drainage (SAGD) is the largest in-situ production process in theCanadian oil-sands. This production process generates large quantities of produced water, typically 3 to 4 timesthe volume of oil, which must be treated and recycled to ensure that the process is viable and to meet regulatoryrequirements. The produced water must be treated before being fed to the steam generator (boiler) for injectioninto the reservoir as steam. To avoid fouling of the boilers, the water is usually treated by a process of warm orhot lime softening to remove hardness and silica which can scale the boilers. This process is high cost andgenerates significant volumes of sludge. An alternative process, so-called zero lime softening is beingdeveloped by the industry partner, Eco-Tech, which is lower cost and more environmentally freindly.Eco-Tech have shown that if the produced water is treated to remove hardness, the silica can be at a relativelyhigh concentration (>200 mg/L), without causing significant scaling of the boilers. However, the concentratestream from the boilers contains greater than 1200 mg/L silica, and must be treated prior to recycle or disposal.Conventional chemical processes (acidification) lead to a silica gel sludge which is difficult o separate from thewater. Electrocoagulation (EC), has been identified as a potential treatment process for the blowdownconcentrate. In previous work, we have been found that EC can effectively remove silica from SAGD producedwater. This project will investigate EC for the treatment of blowdown concentrate generated by the zero-limesoftening process. The treatment performance and filterability of the sludge will be investigated as a function ofthe operating conditions and design of the EC system.