Grant: Engage Grants Program
University of British Columbia
$25,000.00
Development of wireless in-situ sensors for dissolved gases in liquid waste
FY 2016-17
Summary
The greater Vancouver is a dense urban area producing 1 billion liters/day of liquid waste creating anenvironment where toxic hydrogen sulfide (directly produced in the liquid phase in pipelines) is converted tothe highly corrosive sulfuric acid produced in the vapor phase, which can cause significant damage to sewerinfrastructure. Metro Vancouver, including four separate corporate entities, is the sole provider of wastewatertreatment in the greater Vancouver responsible for collecting and treating wastewater through a collectionsystem consisting of over 500 km of sewers, 33 pump stations, five wastewater treatment plants and othersupport facilities. Despite the use of powerful ventilation systems and fixed gas monitors, hydrogen sulfidemay travel many kilometers before entering the air in the pipe headspace. Since hydrogen sulfide gas is bothmalodorous and toxic, using an approach that solely examines hydrogen sulfide can also pose serious healthrisks to employees. Thus, there is high demand for in-situ sensors that can accurately detect hydrogen sulfidelevels in the ""liquid-phase"" in sewer pipes to determine locations with a high corrosion risk. The off-the-shelfdetection devices for waterborne sulfides are cheap, durable and have high sensitivity; however, they lackselectivity among different chemical species that are present in a sewer environment. In this project, and in fullcollaboration with Metro Vancouver, the applicant will develop a detection system enabling the rapidrecognition and measurement of ""liquid-phase"" hydrogen sulfide gas in the ppm range in the sewer pipeline.For this purpose, a continuous flow microfluidic device containing fabricate diffusion channels will bedeveloped to enhance selectivity for certain gas mixtures present in a sewer pipeline. The general compositionof the dissolved gases in the liquid waste will be determined using mass spectrometry (MS), the results ofwhich will be used for calibration and characterization of the proposed detection system. Finally, the devicethen be implemented and examined in a simulated testing environment at the Annacis Research Centre.
Program
Engage Grants Program
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
499463-2016
Name nom
Hoorfar, Mina
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
400
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Environment
Area of application fr
Environnement
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
Development of wireless in-situ sensors for dissolved gases in liquid waste
Keyword
NSERC
Application summary
The greater Vancouver is a dense urban area producing 1 billion liters/day of liquid waste creating anenvironment where toxic hydrogen sulfide (directly produced in the liquid phase in pipelines) is converted tothe highly corrosive sulfuric acid produced in the vapor phase, which can cause significant damage to sewerinfrastructure. Metro Vancouver, including four separate corporate entities, is the sole provider of wastewatertreatment in the greater Vancouver responsible for collecting and treating wastewater through a collectionsystem consisting of over 500 km of sewers, 33 pump stations, five wastewater treatment plants and othersupport facilities. Despite the use of powerful ventilation systems and fixed gas monitors, hydrogen sulfidemay travel many kilometers before entering the air in the pipe headspace. Since hydrogen sulfide gas is bothmalodorous and toxic, using an approach that solely examines hydrogen sulfide can also pose serious healthrisks to employees. Thus, there is high demand for in-situ sensors that can accurately detect hydrogen sulfidelevels in the ""liquid-phase"" in sewer pipes to determine locations with a high corrosion risk. The off-the-shelfdetection devices for waterborne sulfides are cheap, durable and have high sensitivity; however, they lackselectivity among different chemical species that are present in a sewer environment. In this project, and in fullcollaboration with Metro Vancouver, the applicant will develop a detection system enabling the rapidrecognition and measurement of ""liquid-phase"" hydrogen sulfide gas in the ppm range in the sewer pipeline.For this purpose, a continuous flow microfluidic device containing fabricate diffusion channels will bedeveloped to enhance selectivity for certain gas mixtures present in a sewer pipeline. The general compositionof the dissolved gases in the liquid waste will be determined using mass spectrometry (MS), the results ofwhich will be used for calibration and characterization of the proposed detection system. Finally, the devicethen be implemented and examined in a simulated testing environment at the Annacis Research Centre.