Grant: Discovery Grants Program - Individual
University of Manitoba
$33,000.00
""Design, Calibration, and Inversion Algorithms for Novel Microwave Tomography Systems""
FY 2012-13
Summary
The main research goal of this proposed research program is to improve the performance of Microwave Tomography (MWT) systems for biomedical imaging applications. MWT uses microwave measurements to create a quantitative image of the bulk-electrical material properties of an object-of-interest (OI); typically the complex permittivity of the OI. In biomedical applications the OIs are typically in situ regions of the human body and the goal is to use the constructed complex permittivity maps to identify abnormal or diseased tissue in that region, e.g., the imaging and detection of cancerous tissue. The unique advantage of MWT for biomedical diagnostic imaging is that the reconstructed permittivity map is not directly imaged in any other modality and therefore contains unique and complementary information upon which to base a diagnosis. For biomedical applications, the greatest performance issue with current state-of-the-art MWT systems is the limited spatial resolution compared to other imaging modalities such as CT and MRI. In order to be a viable modality the achievable resolution of MWT must be increased while retaining the accuracy of the reconstructed complex permittivity maps. To achieve this goal the proposed research will investigation the three main aspects of MWT: a) the inversion algorithms used to create the images from appropriately calibrated scattered field data, b) the calibration techniques which take raw measurements from the MWT systems and produce appropriate data for the inversion algorithms, and c) the MWT system set-ups themselves which affect the electromagnetic (EM) model which must be used as well as the calibration procedure. These three aspects of MWT are interrelated, in sometimes subtle ways, and it is a fundamental thesis of this proposed research that a substantial enhancement of current MWT imaging performance can only be accomplished via the joint study of these three aspects.
Program
Discovery Grants Program - Individual
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
121454-2012
Name nom
LoVetri, Joe
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
33000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2520
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Microwave and millimeterwave devices, circuits and technologies
Research subject fr
Dispositifs, circuits et technologie hyperfréquences et d'ondes millimétriques
Partie
1
Nb partie
5
Application title
""Design, Calibration, and Inversion Algorithms for Novel Microwave Tomography Systems""
Keyword
NSERC
Application summary
The main research goal of this proposed research program is to improve the performance of Microwave Tomography (MWT) systems for biomedical imaging applications. MWT uses microwave measurements to create a quantitative image of the bulk-electrical material properties of an object-of-interest (OI); typically the complex permittivity of the OI. In biomedical applications the OIs are typically in situ regions of the human body and the goal is to use the constructed complex permittivity maps to identify abnormal or diseased tissue in that region, e.g., the imaging and detection of cancerous tissue. The unique advantage of MWT for biomedical diagnostic imaging is that the reconstructed permittivity map is not directly imaged in any other modality and therefore contains unique and complementary information upon which to base a diagnosis. For biomedical applications, the greatest performance issue with current state-of-the-art MWT systems is the limited spatial resolution compared to other imaging modalities such as CT and MRI. In order to be a viable modality the achievable resolution of MWT must be increased while retaining the accuracy of the reconstructed complex permittivity maps. To achieve this goal the proposed research will investigation the three main aspects of MWT: a) the inversion algorithms used to create the images from appropriately calibrated scattered field data, b) the calibration techniques which take raw measurements from the MWT systems and produce appropriate data for the inversion algorithms, and c) the MWT system set-ups themselves which affect the electromagnetic (EM) model which must be used as well as the calibration procedure. These three aspects of MWT are interrelated, in sometimes subtle ways, and it is a fundamental thesis of this proposed research that a substantial enhancement of current MWT imaging performance can only be accomplished via the joint study of these three aspects.