Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments

University of Toronto

$150,000.00

Nanometer-to-micrometer Length Scale Mechanical and Tribological Characterization System

FY 2022-23

Summary
Surface properties (wear resistance, hardness, surface deformation) are critical to the performance requirements of many components and devices, such as biomedical devices and aerospace applications. To establish a relation between nano- and microstructure and mechanical response of material surfaces, it is important to be able to characterize local structural deformations at high resolution using nanomechanical testing for a broad range of tailored surface chemistries, films or coatings. This proposal requests a robust and all-encompassing advanced nanoindentation system (Bruker TS 77 Nanoindenter) which features an in-situ Scanning Probe Microscopy (SPM) visualization system, to simultaneously perform SPM imaging of a material surface structure, while performing nano-micrometer length scale mechanical and tribological analysis. Nanoindentation has become a powerful alternative to measure elastic modulus, hardness, creep, stress relaxation, and fracture toughness at small scales, with full control over the indenter loading and unloading rates, dynamic oscillation, peak load, and other test parameters. This technique is not limited only to surface engineering technologies but can also be used to investigate the nanometer-to-micrometer length scale mechanical and tribological behaviour of materials in general, such as: analysis of different phases in multi-phases materials, fibre-matrix interfaces in composite materials and microstructural analysis of bulk materials. The TS 77 has the unique feature of using the same probe to raster the sample surface for topography imaging (SPM) as it does to conduct the nanomechanical test, which facilitates the positioning on desired testing sites. This ability to visualize the sample surface on the same length scale as the testing grant superior nanomechanical characterization results and data reliability. Thus, nanometer precision test placement accuracy can be achieved, which ensures that the test is being conducted at the exact desired location on the material. Additionally, by using the in-situ SPM imaging capabilities on the TS 77, quantitative wear volumes and wear removal rates can be measured as a function of applied contact force, sliding speed, and number of passes, which cannot be performed in a traditional nanoindenter system. Due to the scale of testing, tribological performance of individual microstructures, interfaces, and thin films can readily be measured. Currently, there are no in situ SPM imaging nanoindentation systems available in the Toronto region. We suggest the TS 77 will be of significant value for the research, design, and optimization of engineered materials, within the academic research and industrial communities.
Program
Research Tools and Instruments
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RTI-2023-00432
Name nom
Azhari, Faezeh
Department département
Materials Science and Engineering - Materials Science and Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2023
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1611
Committee name en
Materials and Chemical Engineering (RTI)
Committee name fr
Génie chimique et des matériaux (OIR)
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Installment
inst:1
Partie
1
Nb partie
1
Application title
Nanometer-to-micrometer Length Scale Mechanical and Tribological Characterization System
Application summary
Surface properties (wear resistance, hardness, surface deformation) are critical to the performance requirements of many components and devices, such as biomedical devices and aerospace applications. To establish a relation between nano- and microstructure and mechanical response of material surfaces, it is important to be able to characterize local structural deformations at high resolution using nanomechanical testing for a broad range of tailored surface chemistries, films or coatings. This proposal requests a robust and all-encompassing advanced nanoindentation system (Bruker TS 77 Nanoindenter) which features an in-situ Scanning Probe Microscopy (SPM) visualization system, to simultaneously perform SPM imaging of a material surface structure, while performing nano-micrometer length scale mechanical and tribological analysis. Nanoindentation has become a powerful alternative to measure elastic modulus, hardness, creep, stress relaxation, and fracture toughness at small scales, with full control over the indenter loading and unloading rates, dynamic oscillation, peak load, and other test parameters. This technique is not limited only to surface engineering technologies but can also be used to investigate the nanometer-to-micrometer length scale mechanical and tribological behaviour of materials in general, such as: analysis of different phases in multi-phases materials, fibre-matrix interfaces in composite materials and microstructural analysis of bulk materials. The TS 77 has the unique feature of using the same probe to raster the sample surface for topography imaging (SPM) as it does to conduct the nanomechanical test, which facilitates the positioning on desired testing sites. This ability to visualize the sample surface on the same length scale as the testing grant superior nanomechanical characterization results and data reliability. Thus, nanometer precision test placement accuracy can be achieved, which ensures that the test is being conducted at the exact desired location on the material. Additionally, by using the in-situ SPM imaging capabilities on the TS 77, quantitative wear volumes and wear removal rates can be measured as a function of applied contact force, sliding speed, and number of passes, which cannot be performed in a traditional nanoindenter system. Due to the scale of testing, tribological performance of individual microstructures, interfaces, and thin films can readily be measured. Currently, there are no in situ SPM imaging nanoindentation systems available in the Toronto region. We suggest the TS 77 will be of significant value for the research, design, and optimization of engineered materials, within the academic research and industrial communities.
University of Toronto - $150,000 Grant (2022-23) | Canada Spends