Grant: Discovery Grants Program - Individual
Simon Fraser University
$42,000.00
Instrumentation for real-time in vivo fluorescence lifetime imaging
FY 2023-24
Summary
INTRODUCTION Fluorescence imaging has shown promise for the detection of early cancers in excised tissue samples on a microscope, however, the translation of fluorescence imaging to very small single-fiber endoscopes for the detection of cancers deep within the body remains challenging. The endogenous tissue fluorescence which is detected to discriminate normal from precancerous tissue is exceptionally weak. The intensity of the autofluorescence light generated in the system components of a single-fiber endoscope, primarily in the optical fiber itself and elements in the optical path, is of the same order of magnitude as that generated in the tissue. Even when low-fluorescence fibers (pure silica core) are employed to image tissue with relatively bright endogenous fluorescence, the signal-to-background ratio is not much better than 2. In other tissues, where the tissue fluorescence signal is weaker, the tissue fluorescence falls below the level of the background rendering the measurement useless. The application of more advanced techniques, such as fluorescence lifetime imaging (FLIM), which can be used to determine the specific fluorophores responsible for the tissue fluorescence (improving the specificity of detection), are challenging as this technique resolves the fluorescence signal by lifetime, requiring even higher signal-to-background ratio. OBJECTIVES The overarching goal of this proposal is to develop instrumentation for time-resolved fluorescence (lifetime) imaging that can be used with existing single-fiber endoscopes that employ blue light excitation and green light emission for the detection of precancer. The intent of the time-gate is to reject fluorescence generated by the system while allowing tissue fluorescence to be detected. The short-term objective is to develop a hardware platform for time-resolved fluorescence to improve the signal-to-background ratio of fluorescence imaging in a fiber-based system. The long-term objective is the development of a time-resolved subsystem to perform real-time FLIM. NOVETY AND EXPECTED SIGNIFICANCE This program aims to develop instrumentation that would enable time-resolved fluorescence imaging in a single-fiber endoscope using blue excitation. The acquisition platform would employ time-series averaging and deconvolution implemented in firmware to enable fluorescence imaging with high signal-to-background ratio and the potential to perform real-time FLIM. There have been no clinical FLIM devices reported in the literature that use blue excitation. FLIM with blue excitation reduced solarization of the optical fiber and enables the collection of lifetime data from fluorophores that excite in the blue and are associated with the progression of precancer (FAD, collagen, elastin). This work may lead to new endoscopic devices for the early detection of cancer.
Program
Discovery Grants Program - Individual
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2023-05592
Name nom
Lane, Pierre
Department département
Integrative Oncology
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2023
Award amount
42000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Biological and Medical Physics
Research subject en
Physique
Research subject fr
Physique biologique et médicale
Application title
Instrumentation for real-time in vivo fluorescence lifetime imaging
Keyword
Autofluorescence Imaging; Biophotonics; Cancer Imaging; Fluorescence lifetime imaging; Instrumentation; Medical Devices; Optical Coherence Tomography
Application summary
INTRODUCTION Fluorescence imaging has shown promise for the detection of early cancers in excised tissue samples on a microscope, however, the translation of fluorescence imaging to very small single-fiber endoscopes for the detection of cancers deep within the body remains challenging. The endogenous tissue fluorescence which is detected to discriminate normal from precancerous tissue is exceptionally weak. The intensity of the autofluorescence light generated in the system components of a single-fiber endoscope, primarily in the optical fiber itself and elements in the optical path, is of the same order of magnitude as that generated in the tissue. Even when low-fluorescence fibers (pure silica core) are employed to image tissue with relatively bright endogenous fluorescence, the signal-to-background ratio is not much better than 2. In other tissues, where the tissue fluorescence signal is weaker, the tissue fluorescence falls below the level of the background rendering the measurement useless. The application of more advanced techniques, such as fluorescence lifetime imaging (FLIM), which can be used to determine the specific fluorophores responsible for the tissue fluorescence (improving the specificity of detection), are challenging as this technique resolves the fluorescence signal by lifetime, requiring even higher signal-to-background ratio. OBJECTIVES The overarching goal of this proposal is to develop instrumentation for time-resolved fluorescence (lifetime) imaging that can be used with existing single-fiber endoscopes that employ blue light excitation and green light emission for the detection of precancer. The intent of the time-gate is to reject fluorescence generated by the system while allowing tissue fluorescence to be detected. The short-term objective is to develop a hardware platform for time-resolved fluorescence to improve the signal-to-background ratio of fluorescence imaging in a fiber-based system. The long-term objective is the development of a time-resolved subsystem to perform real-time FLIM. NOVETY AND EXPECTED SIGNIFICANCE This program aims to develop instrumentation that would enable time-resolved fluorescence imaging in a single-fiber endoscope using blue excitation. The acquisition platform would employ time-series averaging and deconvolution implemented in firmware to enable fluorescence imaging with high signal-to-background ratio and the potential to perform real-time FLIM. There have been no clinical FLIM devices reported in the literature that use blue excitation. FLIM with blue excitation reduced solarization of the optical fiber and enables the collection of lifetime data from fluorophores that excite in the blue and are associated with the progression of precancer (FAD, collagen, elastin). This work may lead to new endoscopic devices for the early detection of cancer.