Grant: Engage Plus Grants Program
McMaster University
$12,500.00
Optimal Bandwidth-Limited Gradient Waveform Design (continued)
FY 2017-18
Summary
Synaptive Medical is a medical device and software technology company based in Toronto, focused onproviding imaging solutions to enhance neurosurgical procedures. Synaptive Medical is focused onincorporation of novel magnetic resonance imaging technologies into specific neurosurgical procedures tofacilitate tumor detection and resection, guidance of neuro-stimulation devices for degenerative diseases andintervention for stroke and trauma. By increasing the efficiency of MRI experiments, we can reduce the costper diagnosis, and reduce the time spend in the magnet by patients. MRI devices require very flexible software,capable of producing many different types of images, and even quantitative information, like the volume ofblood flowing through an artery.In this project, we will be optimizing one aspect of MRI software called gradient waveforms, which amongother things determine the positioning and resolution of the images. Rather than designing generic waveforms,and accepting that the effective waveform will vary from the design and from machines to machine, wepropose to design waveforms at the highest level of performance available to each specific machine, and insome cases, for each location of the imaging slice within the possible imaging volume. The main problems wewill be avoiding are the distortion of the gradient caused by the limited capabilities of the amplifiers whichdrive current through the specially-shaped conductors called gradient coils, and the unwanted noise caused as aside effect.Under a previous ENGAGE award, we were able to substantially solve this problem for the case ofEcho-Planar Imaging (EPI). During the ENGAGE Plus, we hope to extend those results to Fast Spin Echo(FSE) and Steady-State Free Precession (SSFP) experiments.
Program
Engage Plus Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
514059-2017
Name nom
Anand, Christopher
Department département
Computing and Software
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
12500
Program id
EGP2
Program name en
Engage Plus Grants Program
Program name fr
Programme de subvention d'engagement partenarial Plus
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2715
Research subject group en
Information technology
Research subject group fr
Technologie de l'information
Research subject en
Optimization
Research subject fr
Optimisation
Partie
1
Nb partie
1
Application title
Optimal Bandwidth-Limited Gradient Waveform Design (continued)
Keyword
NSERC
Application summary
Synaptive Medical is a medical device and software technology company based in Toronto, focused onproviding imaging solutions to enhance neurosurgical procedures. Synaptive Medical is focused onincorporation of novel magnetic resonance imaging technologies into specific neurosurgical procedures tofacilitate tumor detection and resection, guidance of neuro-stimulation devices for degenerative diseases andintervention for stroke and trauma. By increasing the efficiency of MRI experiments, we can reduce the costper diagnosis, and reduce the time spend in the magnet by patients. MRI devices require very flexible software,capable of producing many different types of images, and even quantitative information, like the volume ofblood flowing through an artery.In this project, we will be optimizing one aspect of MRI software called gradient waveforms, which amongother things determine the positioning and resolution of the images. Rather than designing generic waveforms,and accepting that the effective waveform will vary from the design and from machines to machine, wepropose to design waveforms at the highest level of performance available to each specific machine, and insome cases, for each location of the imaging slice within the possible imaging volume. The main problems wewill be avoiding are the distortion of the gradient caused by the limited capabilities of the amplifiers whichdrive current through the specially-shaped conductors called gradient coils, and the unwanted noise caused as aside effect.Under a previous ENGAGE award, we were able to substantially solve this problem for the case ofEcho-Planar Imaging (EPI). During the ENGAGE Plus, we hope to extend those results to Fast Spin Echo(FSE) and Steady-State Free Precession (SSFP) experiments.