Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

École de technologie supérieure

$27,000.00

Centering HVAC system design and operation on the occupant : early childhood educational spaces

FY 2022-23

Summary
Thermal comfort assessment and indoor environment quality evaluations have existed for a number of years. Due to the absence of any regulatory mandate, high cost of measuring equipment, limitations of numerical simulation tools and difficulty in finding the parameter values for the equations involved, the industry often omits indoor environmental assessment altogether. For unconventional occupants, this can lead to discomfort. Various low-energy heating, ventilation and air-conditioning (HVAC) system operation principles can appear counterintuitive to occupants, leading them to inadvertently reduce system performance when making changes to their environment with the goal of improving their personal comfort. Energy efficient HVAC system operation is reliant on occupant comfort. When monitoring systems require occupants to express their discomfort for operation settings to be changed, vulnerable occupant groups such as toddlers and young children cannot obtain satisfaction. They also cannot make use of most adaptive behaviour to restore their comfort such as opening windows, altering clothing levels or operation setpoints. The objective of this research program is to address these requirements, starting with a focus on occupant-centric design and operation of early childhood educational (ECE) facilities. The global objective of this research program is to explore methods to ensure the long-term energy efficiency of Heating, Ventilation and Air Conditioning (HVAC) systems in institutional buildings by centering design and operation on occupant comfort. To begin, early childhood educational spaces (<8y) including both child development centers (<6y) and elementary schools (4-11y) will be targeted. This research program aims: 1) to improve the analysis of radiant thermal effects on children, 2) to determine the operational limits of radiant floor heating systems compatible with ECE occupant comfort, and 3) to quantify the performance of displacement ventilation systems used in ECE facilities. This work will provide insight into the appropriate design conditions for spaces where the predominant occupants (toddlers and young children) have a distinctive physiology and metabolism. Results will better define the adequate operational limits of radiant floor heating and displacement ventilation systems in ECE spaces. Situations where indoor environment quality calculation parameters need to be customized will become clearer and results will inform guidelines for HVAC system designers. The latter will have direct impact on industry practices, as will the expertise developed by the HQPs involved. Environmental and economic benefits from improved energy efficiency are to be expected but, more importantly, the increased academic performance of pupils will be the largest long-term impact of this research.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2020-04986
Name nom
D'Avignon, Katherine
Department département
Génie de la construction - Génie de la construction
Organization id
53
Institution établissement
École de technologie supérieure
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2020
Award amount
27000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Installment
inst:3
Partie
1
Nb partie
5
Application title
Centering HVAC system design and operation on the occupant : early childhood educational spaces
Application summary
Thermal comfort assessment and indoor environment quality evaluations have existed for a number of years. Due to the absence of any regulatory mandate, high cost of measuring equipment, limitations of numerical simulation tools and difficulty in finding the parameter values for the equations involved, the industry often omits indoor environmental assessment altogether. For unconventional occupants, this can lead to discomfort. Various low-energy heating, ventilation and air-conditioning (HVAC) system operation principles can appear counterintuitive to occupants, leading them to inadvertently reduce system performance when making changes to their environment with the goal of improving their personal comfort. Energy efficient HVAC system operation is reliant on occupant comfort. When monitoring systems require occupants to express their discomfort for operation settings to be changed, vulnerable occupant groups such as toddlers and young children cannot obtain satisfaction. They also cannot make use of most adaptive behaviour to restore their comfort such as opening windows, altering clothing levels or operation setpoints. The objective of this research program is to address these requirements, starting with a focus on occupant-centric design and operation of early childhood educational (ECE) facilities. The global objective of this research program is to explore methods to ensure the long-term energy efficiency of Heating, Ventilation and Air Conditioning (HVAC) systems in institutional buildings by centering design and operation on occupant comfort. To begin, early childhood educational spaces (<8y) including both child development centers (<6y) and elementary schools (4-11y) will be targeted. This research program aims: 1) to improve the analysis of radiant thermal effects on children, 2) to determine the operational limits of radiant floor heating systems compatible with ECE occupant comfort, and 3) to quantify the performance of displacement ventilation systems used in ECE facilities. This work will provide insight into the appropriate design conditions for spaces where the predominant occupants (toddlers and young children) have a distinctive physiology and metabolism. Results will better define the adequate operational limits of radiant floor heating and displacement ventilation systems in ECE spaces. Situations where indoor environment quality calculation parameters need to be customized will become clearer and results will inform guidelines for HVAC system designers. The latter will have direct impact on industry practices, as will the expertise developed by the HQPs involved. Environmental and economic benefits from improved energy efficiency are to be expected but, more importantly, the increased academic performance of pupils will be the largest long-term impact of this research.
École de technologie supérieure - $27,000 Grant (2022… | Canada Spends