Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Alberta

$24,950.00

Engineering a mechanical surrogate neck-form for impact testing

FY 2016-17

Summary
Currently, helmet test methods use linear drop assemblies that guide a K1A magnesium headform onto an impact anvil. The magnesium head is constrained to experience only linear acceleration because it is attached to the linear guide via a rigid metal neck. While it was not originally designed to do so, this impact simulation method does not recreate the mechanics of helmeted impact with a human, where the head is supported and kinematically influenced by a neck capable of displacing/rotating along six degrees of freedom (and which allows the head to rotate and experience angular kinematics). Some of the new proposed test methods for helmet certification with angular kinematics have suggested that biofidelic head-neck models should replace the magnesium head and rigid neck methods. Biofidelic head models that are currently available include the NOCSAE and HybridIII headforms, both of which attempt to recreate anthropometry and inertial properties of the human head. Currently available neck models, the most common of which used in helmet testing is the HybridIII neck, are not considered to give realistic response in helmeted impact, and as a result the certification organizations are discussing what, if any, neck model could and should be used for helmet certification. The HybridIII, and other neck models, are accepted to be much too mechanically stiff in axial rotation and axial compression. This is perhaps not surprising given the original purpose of the HybridIII neck, which was to realistically simulate fore-aft rotational response in frontal automotive impacts. The objective of this partnership with Biokinetics and Associates Ltd. (Ottawa ON) is to take the first steps towards prototyping a biofidelic neck model suitable for use in helmet certification.
Program
Engage Grants Program
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
499175-2016
Name nom
Dennison, Christopher
Department département
Mechanical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
24950
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Partie
1
Nb partie
1
Application title
Engineering a mechanical surrogate neck-form for impact testing
Keyword
NSERC
Application summary
Currently, helmet test methods use linear drop assemblies that guide a K1A magnesium headform onto an impact anvil. The magnesium head is constrained to experience only linear acceleration because it is attached to the linear guide via a rigid metal neck. While it was not originally designed to do so, this impact simulation method does not recreate the mechanics of helmeted impact with a human, where the head is supported and kinematically influenced by a neck capable of displacing/rotating along six degrees of freedom (and which allows the head to rotate and experience angular kinematics). Some of the new proposed test methods for helmet certification with angular kinematics have suggested that biofidelic head-neck models should replace the magnesium head and rigid neck methods. Biofidelic head models that are currently available include the NOCSAE and HybridIII headforms, both of which attempt to recreate anthropometry and inertial properties of the human head. Currently available neck models, the most common of which used in helmet testing is the HybridIII neck, are not considered to give realistic response in helmeted impact, and as a result the certification organizations are discussing what, if any, neck model could and should be used for helmet certification. The HybridIII, and other neck models, are accepted to be much too mechanically stiff in axial rotation and axial compression. This is perhaps not surprising given the original purpose of the HybridIII neck, which was to realistically simulate fore-aft rotational response in frontal automotive impacts. The objective of this partnership with Biokinetics and Associates Ltd. (Ottawa ON) is to take the first steps towards prototyping a biofidelic neck model suitable for use in helmet certification.