Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments

McGill University

$150,000.00

Cryo-3D-super-resolution light microscope for correlative microscopy

FY 2021-22

Summary
We will build a super-resolution light microscope capable of imaging samples at liquid nitrogen- temperature in 3D with multiple colours. Structured illumination microscopes (SIM) can overcome the diffraction limit by employing a cleverly modulated illumination system. The resulting 3D images will allow structural features within cells to be localized to within ~100nm. We use samples rapidly frozen in liquid ethane to fix the samples in a layer of vitreous ice, preserving molecular interactions in a pristine state. While this method has numerous advantages over chemical fixation, it also decreases the photosensitivity of the fluorophores, making photobleaching less of a problem, and increasing the effective detectability of labeled molecules. However, the sample must remain below the recrystallisation temperature of water (roughly --140 C). A high degree of precision in localizing labels within frozen samples is required for correlation in a focused ion beam (FIB), and subsequent imaging of molecular details by cryo-electron microscopy (cryoEM). A thick cell, containing a feature of interest at some depth, can be "milled" with a FIB, so that only a thin frozen layer of the pristinely preserved cell remains. To obtain the best resolution by cryoEM, the thin layer should be roughly 150nm thick. Targeting the correct 150nm layer in a cell requires very accurate correlative signal, but this correlative approach can deliver spectacular detail of the molecular environment surrounding proteins of interest, and can even result in high resolution in situ macromolecular complex structures by combining cryo--electron tomography and subtomogram averaging. The microscope design will allow us to perform 4--colour 3D scans and reconstruct them in real-time to give us multiple simultaneous signals for increased cellular context. This also allows us to screen samples for suitability before the time-intensive FIB--milling step. Our group of 5 investigators at McGill University will use this microscopy workflow to look at dynamic features in the cytoskeleton, including actin filament assembly, microtubule formation, and centrosome disassembly, as well as the electrical interconnection of conductive microbial biofilms, and the molecular mechanism of non-enveloped virus infection.
Program
Research Tools and Instruments
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RTI-2022-00350
Name nom
Strauss, Mike
Department département
Anatomy and Cell Biology
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2022
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1602
Committee name en
Biological Systems and Functions (RTI)
Committee name fr
Systèmes et fonctions biologiques (OIR)
Area of application code
1201
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Life sciences (including biotechnology)
Area of application fr
Sciences de la vie (y compris biotechnologie)
Research subject code
5110
Research subject group en
Cell biology
Research subject group fr
Biologie cellulaire
Research subject en
Cytoskeleton
Research subject fr
Cytosquelette
Installment
inst:1
Partie
1
Nb partie
1
Application title
Cryo-3D-super-resolution light microscope for correlative microscopy
Keyword
NSERC
Application summary
We will build a super-resolution light microscope capable of imaging samples at liquid nitrogen- temperature in 3D with multiple colours. Structured illumination microscopes (SIM) can overcome the diffraction limit by employing a cleverly modulated illumination system. The resulting 3D images will allow structural features within cells to be localized to within ~100nm. We use samples rapidly frozen in liquid ethane to fix the samples in a layer of vitreous ice, preserving molecular interactions in a pristine state. While this method has numerous advantages over chemical fixation, it also decreases the photosensitivity of the fluorophores, making photobleaching less of a problem, and increasing the effective detectability of labeled molecules. However, the sample must remain below the recrystallisation temperature of water (roughly --140 C). A high degree of precision in localizing labels within frozen samples is required for correlation in a focused ion beam (FIB), and subsequent imaging of molecular details by cryo-electron microscopy (cryoEM). A thick cell, containing a feature of interest at some depth, can be "milled" with a FIB, so that only a thin frozen layer of the pristinely preserved cell remains. To obtain the best resolution by cryoEM, the thin layer should be roughly 150nm thick. Targeting the correct 150nm layer in a cell requires very accurate correlative signal, but this correlative approach can deliver spectacular detail of the molecular environment surrounding proteins of interest, and can even result in high resolution in situ macromolecular complex structures by combining cryo--electron tomography and subtomogram averaging. The microscope design will allow us to perform 4--colour 3D scans and reconstruct them in real-time to give us multiple simultaneous signals for increased cellular context. This also allows us to screen samples for suitability before the time-intensive FIB--milling step. Our group of 5 investigators at McGill University will use this microscopy workflow to look at dynamic features in the cytoskeleton, including actin filament assembly, microtubule formation, and centrosome disassembly, as well as the electrical interconnection of conductive microbial biofilms, and the molecular mechanism of non-enveloped virus infection.
McGill University - $150,000 Grant (2021-22) | Canada Spends