Grant: Idea to Innovation

Simon Fraser University

$14,972.00

Market Assessment Study of Leech-mimic 3D Printed Origami Sensor to Monitor Electrophysiological Signals

FY 2022-23

Summary
The Simon Fraser University Technology Licensing Office has Adventus work on a market assessment study supported through the NSERC Idea to Innovation grant program, for a technology entitled "Leech-mimic 3D printed origami (LMO) sensor composed of the non-auxetic tip with auxetic bodies to monitor electrophysiological signals" developed by Dr. Woo Soo Kim, Professor in the School of Mechatronic Systems Engineering at SFU. Monitoring of blood pressure (BP) plays a crucial role in medical diagnosis because high BP is deeply related to several chronic diseases. The increasing prevalence of cardiovascular diseases and the growing aging population are leading to rising demand for personal healthcare systems that collect the BP of patients during their daily life. Therefore, accurate and/or frequent BP monitoring without clinical settings (such as mobile or wearable devices for remote or general healthcare monitoring) is anticipated to drive the global ECG sensor market. In fact, both ECG and PPG (photoplethysmography) technologies are becoming easily available, low-cost, and convenient with portable devices. The pulse arrival time (PAT) parameter, indicating the time taken from the pulse waveforms to traverse from the heart to a distal site, is often used with the paired ECG-PPG sensing system monitoring the BP continuously. The BP monitoring with PAT requires reliable ECG signals near the heart and PPG signals on the distal site. Thus, stable positioning of dry ECG electrodes on the skin is essential to obtain effective ECG signals. SFU researchers have developed a leech-mimic 3D printed origami (LMO) sensor composed of the non-auxetic tip with auxetic bodies to monitor electrophysiological signals. The leech-mimic structure (LMO) provides stable contacts and applies reliable but slight suction to the human skin so that the LMO is still attached to the human skin when the patient is in motion. This dry electrode for cardiovascular monitoring systems makes monitoring time faster and much more comfortable compared to the current wet gel-type electrodes used in monitoring ECG and BP.
Program
Idea to Innovation
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
576572-2022
Name nom
Kim, Woo Soo WS
Department département
Mechatronic Systems Engineering
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2022
Award amount
14972
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Installment
inst:1
Partie
1
Nb partie
1
Application title
Market Assessment Study of Leech-mimic 3D Printed Origami Sensor to Monitor Electrophysiological Signals
Application summary
The Simon Fraser University Technology Licensing Office has Adventus work on a market assessment study supported through the NSERC Idea to Innovation grant program, for a technology entitled "Leech-mimic 3D printed origami (LMO) sensor composed of the non-auxetic tip with auxetic bodies to monitor electrophysiological signals" developed by Dr. Woo Soo Kim, Professor in the School of Mechatronic Systems Engineering at SFU. Monitoring of blood pressure (BP) plays a crucial role in medical diagnosis because high BP is deeply related to several chronic diseases. The increasing prevalence of cardiovascular diseases and the growing aging population are leading to rising demand for personal healthcare systems that collect the BP of patients during their daily life. Therefore, accurate and/or frequent BP monitoring without clinical settings (such as mobile or wearable devices for remote or general healthcare monitoring) is anticipated to drive the global ECG sensor market. In fact, both ECG and PPG (photoplethysmography) technologies are becoming easily available, low-cost, and convenient with portable devices. The pulse arrival time (PAT) parameter, indicating the time taken from the pulse waveforms to traverse from the heart to a distal site, is often used with the paired ECG-PPG sensing system monitoring the BP continuously. The BP monitoring with PAT requires reliable ECG signals near the heart and PPG signals on the distal site. Thus, stable positioning of dry ECG electrodes on the skin is essential to obtain effective ECG signals. SFU researchers have developed a leech-mimic 3D printed origami (LMO) sensor composed of the non-auxetic tip with auxetic bodies to monitor electrophysiological signals. The leech-mimic structure (LMO) provides stable contacts and applies reliable but slight suction to the human skin so that the LMO is still attached to the human skin when the patient is in motion. This dry electrode for cardiovascular monitoring systems makes monitoring time faster and much more comfortable compared to the current wet gel-type electrodes used in monitoring ECG and BP.
Simon Fraser University - $14,972 Grant (2022-23) | Canada Spends