Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Waterloo

$23,882.00

Corrosion of galvanized and chromated lath in stucco

FY 2010-11

Summary
Stucco used on the facades of buildings is based on Portland cement and is very brittle. A three-dimensional wire mesh, termed a lath, is embedded in the stucco to provide reinforcement and to allow bonding to the underlying structure. The mesh is usually constructed from galvanized steel wire and, under normal circumstances, is corrosion resistant. However, on structures within a few kilometres of the coast and, therefore, exposed to salt-laden, moist air, premature rust staining of stucco reinforced by conventional galvanized steel lath has been reported. This is particularly evident at corners of the buildings where there is negligible stucco cover on the corner wires. To provide additional corrosion resistance, the lath is being coated with a thin layer of chromate and lab tests have shown the chromated wire to be exceptionally resistant to salt water, compared with other galvanized products. Unfortunately, when the galvanized, chromated lath is coated with stucco and exposed to salt water, its resistance is less than expected. The proposed project is aimed at determining the nature of the chromate coating and providing an explanation for the superior performance of the uncoated lath in salt solution and for its less stellar performance when embedded in stucco.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
402420-2010
Name nom
Hansson, Carolyn
Department département
Mechanical Engineering and Mechatronics
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
23882
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Partie
1
Nb partie
1
Application title
Corrosion of galvanized and chromated lath in stucco
Keyword
NSERC
Application summary
Stucco used on the facades of buildings is based on Portland cement and is very brittle. A three-dimensional wire mesh, termed a lath, is embedded in the stucco to provide reinforcement and to allow bonding to the underlying structure. The mesh is usually constructed from galvanized steel wire and, under normal circumstances, is corrosion resistant. However, on structures within a few kilometres of the coast and, therefore, exposed to salt-laden, moist air, premature rust staining of stucco reinforced by conventional galvanized steel lath has been reported. This is particularly evident at corners of the buildings where there is negligible stucco cover on the corner wires. To provide additional corrosion resistance, the lath is being coated with a thin layer of chromate and lab tests have shown the chromated wire to be exceptionally resistant to salt water, compared with other galvanized products. Unfortunately, when the galvanized, chromated lath is coated with stucco and exposed to salt water, its resistance is less than expected. The proposed project is aimed at determining the nature of the chromate coating and providing an explanation for the superior performance of the uncoated lath in salt solution and for its less stellar performance when embedded in stucco.