Grant: Discovery Grants Program - Individual
McGill University
$54,000.00
Accurate reference dosimetry of non-standard beams using water calorimetry, ionization chambers and Monte Carlo dose calculations
EF 2009-10
Résumé
Radiation therapy makes use of ionizing radiation to destroy malignant cancerous tissues. The
success of a radiation treatment depends in part on the degree of accuracy to which the prescribed radiation dose (energy deposited per unit mass) can be delivered to the tumour. One generally assumes that the dose in the tumour needs to be accurate to within ±5% for a treatment to be effective. The first step involved in determining the dose to the tumour, is the measurement of the output of the irradiating device, which is, for many types of treatments a linear accelerator but is sometimes also a radioactive source. What is being determined at first is the dose at a specific reference depth in water, because the properties of human tissue with regard to radiation energy deposition are almost identical to water. In further steps, algorithms are being used to calculate dose in the patient at all points of interest based on this measured dose in water and based on anatomical information of the patient in particular. Our research aims to improve the accuracy of dose determination for radiation treatments that are composed of many small radiation fields. Knowing the dose accurately in such combined irradiations is very complex since the individual fields have different intensity. We have developed a special instrument, called a water calorimeter, which measures dose in water directly, by measuring the temperature rise at the point in water for different types of radiation used in the clinic. Since we believe that, with this method, we can measure the dose in different beams to an accuracy of better than 0.5%, we can also calibrate and study the performance of other dosimeter devices which are more easy to operate but whose characteristics are, at this point, only known from calculations. The overall long term effect of better accuracy of clinical dosimetry is better outcome of radiation therapy.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
298191-2009
Name nom
Seuntjens, Jan
Department département
Medical Physics Unit
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2009
Award amount
54000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
29
Committee name en
General Physics
Committee name fr
Physique générale
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
1
Nb partie
5
Application title
Accurate reference dosimetry of non-standard beams using water calorimetry, ionization chambers and Monte Carlo dose calculations
Keyword
NA
Application summary
Radiation therapy makes use of ionizing radiation to destroy malignant cancerous tissues. The
success of a radiation treatment depends in part on the degree of accuracy to which the prescribed radiation dose (energy deposited per unit mass) can be delivered to the tumour. One generally assumes that the dose in the tumour needs to be accurate to within ±5% for a treatment to be effective. The first step involved in determining the dose to the tumour, is the measurement of the output of the irradiating device, which is, for many types of treatments a linear accelerator but is sometimes also a radioactive source. What is being determined at first is the dose at a specific reference depth in water, because the properties of human tissue with regard to radiation energy deposition are almost identical to water. In further steps, algorithms are being used to calculate dose in the patient at all points of interest based on this measured dose in water and based on anatomical information of the patient in particular. Our research aims to improve the accuracy of dose determination for radiation treatments that are composed of many small radiation fields. Knowing the dose accurately in such combined irradiations is very complex since the individual fields have different intensity. We have developed a special instrument, called a water calorimeter, which measures dose in water directly, by measuring the temperature rise at the point in water for different types of radiation used in the clinic. Since we believe that, with this method, we can measure the dose in different beams to an accuracy of better than 0.5%, we can also calibrate and study the performance of other dosimeter devices which are more easy to operate but whose characteristics are, at this point, only known from calculations. The overall long term effect of better accuracy of clinical dosimetry is better outcome of radiation therapy.