Grant: Engage Grants Program
University of Manitoba
$25,000.00
THM reduction feasibility study for the water treatment plant at the Town of Rainy River
EF 2014-15
Résumé
In Manitoba, nearly 70% of potable water treatment plants exceed the standard for the potentially carcinogenicchlorine disinfection by-products - trihalomethanes (THMs). THMs are formed when chlorine reacts withwater Dissolved Organic Carbon (DOC), therefore, quality and quantity of water DOC will affect how muchTHMs are formed.Elevated level of THMs is a major concern for the Town of Rainy River (Ontario). The water treatment plant inRainy River recorded elevated THMs levels in the distribution system often exceed 100 ppb with a maximumreading of 233.3 ppb in July 2010 The current Guideline for Canadian Drinking Water Quality (GCDWQ) hasa THM regulation of 100 ppb which is expected to be lowered to 80 ppb in the near future following the UnitedStates Environmental Protection Agency (USEPA).DOC is typically removed by chemical coagulation, but, the efficiency of this process is quite low. Applicationof peroxidation with potassium permanganate or ozone prior to coagulation is reported to improve thisefficiency; however, ozone dose has to be custom determined for each type of water source. This project aimsto optimize the DOC removal in existing chemical coagulation process at the Town of Rainy River. Severalnew coagulants in combination with peroxidation will be tested. Optimization of the operations of the existingprocess may allow for avoidance of costly water treatment plant upgrades and provide significant savings to thecommunity.This research will study the optimization of coagulation for removal of DOC from waters with low alkalinityand high DOC concentrations. These types of waters are quite common in the Canadian Prairies. ManyCanadian communities with similar surface water quality suffer from high concentrations of THMs and willbenefit from the results of this study.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
463285-2014
Name nom
Gorczyca, Beata
Department département
Civil Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
901
Area of application group en
Commercial services
Area of application group fr
Services commerciaux
Area of application en
Sanitary engineering
Area of application fr
Génie sanitaire
Research subject code
1501
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Water quality, pollution
Research subject fr
Qualité de l'eau, pollution
Partie
1
Nb partie
1
Application title
THM reduction feasibility study for the water treatment plant at the Town of Rainy River
Keyword
NSERC
Application summary
In Manitoba, nearly 70% of potable water treatment plants exceed the standard for the potentially carcinogenicchlorine disinfection by-products - trihalomethanes (THMs). THMs are formed when chlorine reacts withwater Dissolved Organic Carbon (DOC), therefore, quality and quantity of water DOC will affect how muchTHMs are formed.Elevated level of THMs is a major concern for the Town of Rainy River (Ontario). The water treatment plant inRainy River recorded elevated THMs levels in the distribution system often exceed 100 ppb with a maximumreading of 233.3 ppb in July 2010 The current Guideline for Canadian Drinking Water Quality (GCDWQ) hasa THM regulation of 100 ppb which is expected to be lowered to 80 ppb in the near future following the UnitedStates Environmental Protection Agency (USEPA).DOC is typically removed by chemical coagulation, but, the efficiency of this process is quite low. Applicationof peroxidation with potassium permanganate or ozone prior to coagulation is reported to improve thisefficiency; however, ozone dose has to be custom determined for each type of water source. This project aimsto optimize the DOC removal in existing chemical coagulation process at the Town of Rainy River. Severalnew coagulants in combination with peroxidation will be tested. Optimization of the operations of the existingprocess may allow for avoidance of costly water treatment plant upgrades and provide significant savings to thecommunity.This research will study the optimization of coagulation for removal of DOC from waters with low alkalinityand high DOC concentrations. These types of waters are quite common in the Canadian Prairies. ManyCanadian communities with similar surface water quality suffer from high concentrations of THMs and willbenefit from the results of this study.