Grant: Research Tools and Instruments
McGill University
$106,891.00
A powerful suite of instruments to prepare and characterize samples with highly resolved spectral maps for a wide variety of applications
EF 2024-25
Résumé
We propose to build a unique suite of instruments to create flat sections from a wide variety of samples, and collect on them high-quality Raman and FTIR maps to understand their local chemical composition, thanks to (i) a new microtome with a tungsten carbide (WC) blade to cut through both soft and hard samples; (ii) a Raman/FT-Raman microscope with excitation wavelengths in both the visible and near infrared (NIR); (iii) an FTIR microscope that can collect very fast FTIR spectral maps.
Having samples with flat sections is crucial to acquire highly resolved spectral maps. We propose purchasing a WC-microtome because most available microtomes have blades that can only cut through soft samples. However, hard samples are used by researchers working in fields as diverse as biomaterials, electronics, and batteries. The WC blade will allow sectioning these hard samples too.
The Raman/FT-Raman microscope is a system unique in Canada that enables collection of Raman spectra with both visible and NIR excitation thanks to the connection of a Raman microscope and an FT-NIR Raman spectrometer. Radiation is carried between the two instruments through optical cables, allowing collection of Raman spectra with NIR excitation with high signal-to-noise ratio. Such feature is crucial especially for biological samples, which fluoresce under visible excitation. The system is housed in a laboratory shared by Cerruti and Nazhat but needs some maintenance: the connection between the microscope and the FT-NIR spectrometer needs to be fixed; a new 785 nm laser needs to be purchased since the current one is reaching end of life; and the 100X objective, necessary to collect spectral maps with the highest spatial resolution, needs to be replaced.
FTIR microscopes able to collect spatially resolved IR maps are rare. The Spectrum Spotlight, housed in the same lab as the Raman system, is unique due to its array detector that enables extremely rapid collection of spectral maps superimposed on visual images. It urgently needs maintenance to repair the stage, without which it cannot be operated.
Fixing the Raman/FT-Raman and the FTIR microscopes and purchasing a WC-blade microtome will create an all-in-one suite of instruments that will help the advancement of many NSERC-supported projects, in fields ranging from biomaterial development to synthesizing high quality electronic materials. Such an impressive range of applications shows the potential impact of this project, testified by the many high-impact publications of PIs and users on this application.
The instrument suite will be accessible to 69 HQPs from PIs and major users associated to this proposal, and many more. To streamline access, two instruments will be transferred under the McGill Institute of Advanced Materials (MIAM), and the third will be greatly advertised on MIAM platforms and beyond. Excellent hands-on training will be provided by two Research Associates who are familiar with the systems.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RTI-2025-00419
Name nom
Cerruti, Marta
Department département
Mining and Materials Engineering
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2025
Award amount
106891
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1611
Committee name en
Materials and Chemical Engineering (RTI)
Committee name fr
Génie chimique et des matériaux (OIR)
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
2001
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials structure, properties and testing
Research subject fr
Structure, propriétés et essais des matériaux
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
A powerful suite of instruments to prepare and characterize samples with highly resolved spectral maps for a wide variety of applications
Keywords
raman spectroscopy; raman mapping; infrared microscopy; sections; biomaterials; electronic materials; mineralized tissues
Application summary
We propose to build a unique suite of instruments to create flat sections from a wide variety of samples, and collect on them high-quality Raman and FTIR maps to understand their local chemical composition, thanks to (i) a new microtome with a tungsten carbide (WC) blade to cut through both soft and hard samples; (ii) a Raman/FT-Raman microscope with excitation wavelengths in both the visible and near infrared (NIR); (iii) an FTIR microscope that can collect very fast FTIR spectral maps.
Having samples with flat sections is crucial to acquire highly resolved spectral maps. We propose purchasing a WC-microtome because most available microtomes have blades that can only cut through soft samples. However, hard samples are used by researchers working in fields as diverse as biomaterials, electronics, and batteries. The WC blade will allow sectioning these hard samples too.
The Raman/FT-Raman microscope is a system unique in Canada that enables collection of Raman spectra with both visible and NIR excitation thanks to the connection of a Raman microscope and an FT-NIR Raman spectrometer. Radiation is carried between the two instruments through optical cables, allowing collection of Raman spectra with NIR excitation with high signal-to-noise ratio. Such feature is crucial especially for biological samples, which fluoresce under visible excitation. The system is housed in a laboratory shared by Cerruti and Nazhat but needs some maintenance: the connection between the microscope and the FT-NIR spectrometer needs to be fixed; a new 785 nm laser needs to be purchased since the current one is reaching end of life; and the 100X objective, necessary to collect spectral maps with the highest spatial resolution, needs to be replaced.
FTIR microscopes able to collect spatially resolved IR maps are rare. The Spectrum Spotlight, housed in the same lab as the Raman system, is unique due to its array detector that enables extremely rapid collection of spectral maps superimposed on visual images. It urgently needs maintenance to repair the stage, without which it cannot be operated.
Fixing the Raman/FT-Raman and the FTIR microscopes and purchasing a WC-blade microtome will create an all-in-one suite of instruments that will help the advancement of many NSERC-supported projects, in fields ranging from biomaterial development to synthesizing high quality electronic materials. Such an impressive range of applications shows the potential impact of this project, testified by the many high-impact publications of PIs and users on this application.
The instrument suite will be accessible to 69 HQPs from PIs and major users associated to this proposal, and many more. To streamline access, two instruments will be transferred under the McGill Institute of Advanced Materials (MIAM), and the third will be greatly advertised on MIAM platforms and beyond. Excellent hands-on training will be provided by two Research Associates who are familiar with the systems.