Grant: Alliance Grants
Queen's University
$50,000.00
Optical sensor for rapid on site diagnosis of Covid-19_x000d_ _x000d_ _x000d_ _x000d_
EF 2020-21
Résumé
Rapid point of care detection is essential for controlling the Covid-19 pandemic. Optics offer unique advantages compared to other alternatives to achieve this target including high sensitivity, small device size and real time, label free detection. Portable optical sensors proposed so far rely on developing fully packaged optical chips. Although these devices can be very compact, the complicated optical light coupling mechanism required in and out coupling of light results makes these devices very expensive for large scale deployment.
The proposed research aims at developing a new optical sensor technology for detection of SAR-COV-2 virus in saliva. The sensor will be very compact, and instead of using complicated light coupling schemes, it will use commercially available low-cost laser diode and photodetectors. Availability of such a sensor will greatly enhance Canadian capability of monitoring and controlling the Covid-19 pandemic.
Programme
Alliance Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
554966-2020
Name nom
Alam, Muhammad
Department département
Electrical and Computer Engineering
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2020
Award amount
50000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2505
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Photon devices
Research subject fr
Dispositifs photoniques
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Optical sensor for rapid on site diagnosis of Covid-19_x000d_
_x000d_
_x000d_
_x000d_
Keyword
NSERC
Application summary
Rapid point of care detection is essential for controlling the Covid-19 pandemic. Optics offer unique advantages compared to other alternatives to achieve this target including high sensitivity, small device size and real time, label free detection. Portable optical sensors proposed so far rely on developing fully packaged optical chips. Although these devices can be very compact, the complicated optical light coupling mechanism required in and out coupling of light results makes these devices very expensive for large scale deployment.
The proposed research aims at developing a new optical sensor technology for detection of SAR-COV-2 virus in saliva. The sensor will be very compact, and instead of using complicated light coupling schemes, it will use commercially available low-cost laser diode and photodetectors. Availability of such a sensor will greatly enhance Canadian capability of monitoring and controlling the Covid-19 pandemic.