Grant: Discovery Grants Program - Individual
McMaster University
$18,000.00
Constrained imaged registration
EF 2008-09
Résumé
Image registration is a commonly used technique to align images or data acquired from different positions at different times or with different devices. The objective of image registration in a clinical environment is to align these views in order to produce a meaningful diagnosis or treatment planning. For example, the diagnosis and treatment of female breast cancer may require a time series of three-dimensional magnetic resonance images (MRI), visualizing the contrast uptake in the tissue. This uptake, divided into the so-called wash-in and wash-out phases, is of particular interest, since it characterizes tissue properties. Assuming the female breast to be static, a point based analysis would provide the uptake characteristics as a function in time. However, the acquisition time is usually around ten minutes and due to motion of the patient, like heart beat or breathing, the breast is not static and the interpretation of the data is weakened and complicated by motion artifacts.
Registration techniques are used to automatically compensate for image differences that are related to motion. However, common schemes do not prevent a change of volume of the processed data. This is very delicate, if tumor growth is under consideration. For these applications, only a volume preserving scheme guaranties that changes of volume is due to measurement and not to the alignment. Unfortunately, there are only two approaches to deal with volume preservation. The first one is suggested by Torsten Rohlfing et al and uses a spline based parametric transformation and penalty based on the integral over volume changes. This approach has some disadvantages. An alternative approach has been suggested by Eldad Haber and myself and is based on a more general non-parametric transformation and explicit constraints on a voxel basis. The essential advantage of the our approach is that it guarantees volume preservation, as has already been shown. However, this approach is computationally quite demanding and since a rigorous implementation is still missing, it can only handle low-resolution data. More research is needed to make this method clinically available.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
356070-2008
Name nom
Modersitzki, Jan
Department département
Computing and Software
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2008
Competition year année de concours
2008
Award amount
18000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
331
Committee name en
Computing and Information Sciences - B
Committee name fr
Informatique - B
Area of application code
801
Area of application group en
Information and communication services
Area of application group fr
Services d'information et de télécommunications
Area of application en
Computer software
Area of application fr
Logiciel
Research subject code
2708
Research subject group en
Information technology
Research subject group fr
Technologie de l'information
Research subject en
Image processing
Research subject fr
Traitement des images
Partie
1
Nb partie
5
Application title
Constrained imaged registration
Keyword
NA
Application summary
Image registration is a commonly used technique to align images or data acquired from different positions at different times or with different devices. The objective of image registration in a clinical environment is to align these views in order to produce a meaningful diagnosis or treatment planning. For example, the diagnosis and treatment of female breast cancer may require a time series of three-dimensional magnetic resonance images (MRI), visualizing the contrast uptake in the tissue. This uptake, divided into the so-called wash-in and wash-out phases, is of particular interest, since it characterizes tissue properties. Assuming the female breast to be static, a point based analysis would provide the uptake characteristics as a function in time. However, the acquisition time is usually around ten minutes and due to motion of the patient, like heart beat or breathing, the breast is not static and the interpretation of the data is weakened and complicated by motion artifacts.
Registration techniques are used to automatically compensate for image differences that are related to motion. However, common schemes do not prevent a change of volume of the processed data. This is very delicate, if tumor growth is under consideration. For these applications, only a volume preserving scheme guaranties that changes of volume is due to measurement and not to the alignment. Unfortunately, there are only two approaches to deal with volume preservation. The first one is suggested by Torsten Rohlfing et al and uses a spline based parametric transformation and penalty based on the integral over volume changes. This approach has some disadvantages. An alternative approach has been suggested by Eldad Haber and myself and is based on a more general non-parametric transformation and explicit constraints on a voxel basis. The essential advantage of the our approach is that it guarantees volume preservation, as has already been shown. However, this approach is computationally quite demanding and since a rigorous implementation is still missing, it can only handle low-resolution data. More research is needed to make this method clinically available.