Grant: Discovery Grants Program - Individual
University of Alberta
$32,000.00
The design of a light and compact magnet for MRI
EF 2015-16
Résumé
MRI is the best non-invasive diagnostic imaging modality providing high quality images of the entire body. However, its high costs and claustrophobic magnet geometry prevent a faster growth and broader applications. Therefore we propose to address these weaknesses by designing a new magnet suitable for MRI based on the so-called Halbach structure.
Halbach magnets have a cylindrical shape and comprise small magnetic pieces placed on a surface of a cylinder. Although the Halbach design has been known for over 30 years, a full analytical theory of the magnetic field produced by the magnet has been developed only for a very high length/diameter ratio, when the mathematical description of the field can be reduced to two dimensions (2D). A 3D mathematical model of the finite-length magnet (""long"" magnet) with small length/diameter ratio (<1) has been proposed very recently (2014) but a magnet based on this theory has not yet been constructed. Computer programs solving semi-analytical field equations, using the finite elements or the boundary methods to calculate the field have been developed yet not without drawbacks. Furthermore magnet weight or its size have not been optimized so far. In addition, there is no perfect manufacturing process, yet none of the theoretical models include manufacturing errors, such as inconsistent segmentation of the magnetic pieces over the cylinder's surface or their imperfect position.
It is known that, for example, 2D segmentation causes creation of harmonics of the order of a multiple of the number of the segments. To deal with this common problem, the magnetic field over a sphere is analyzed using spherical harmonics. From this analysis, the placement of small compensating magnets is calculated to cancel the spherical harmonics and to improve magnet homogeneity. The field homogeneity may be also improved by correcting positions of the segments. However none of these methods is perfect. In our approach we propose to develop a method of shimming on a surface of a cylinder instead of a sphere, as traditionally used. We expect this approach will provide efficient shimming for ""short"" Halbach magnets.
In summary, we propose to develop a new design of a light, permanent magnet suitable for standard and ""gradient free"" MRI, co-developed by the applicant. As ""gradient free"" MRI does not require gradients of the magnetic field and associated amplifiers, it is feasible to produce inexpensive, light and silent MRI system for many new imaging applications.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2015-03992
Name nom
Tomanek, Boguslaw
Department département
Oncology - Oncology
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
32000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
5
Application title
The design of a light and compact magnet for MRI
Keyword
NSERC
Application summary
MRI is the best non-invasive diagnostic imaging modality providing high quality images of the entire body. However, its high costs and claustrophobic magnet geometry prevent a faster growth and broader applications. Therefore we propose to address these weaknesses by designing a new magnet suitable for MRI based on the so-called Halbach structure.
<br />
Halbach magnets have a cylindrical shape and comprise small magnetic pieces placed on a surface of a cylinder. Although the Halbach design has been known for over 30 years, a full analytical theory of the magnetic field produced by the magnet has been developed only for a very high length/diameter ratio, when the mathematical description of the field can be reduced to two dimensions (2D). A 3D mathematical model of the finite-length magnet (""long"" magnet) with small length/diameter ratio (<1) has been proposed very recently (2014) but a magnet based on this theory has not yet been constructed. Computer programs solving semi-analytical field equations, using the finite elements or the boundary methods to calculate the field have been developed yet not without drawbacks. Furthermore magnet weight or its size have not been optimized so far. In addition, there is no perfect manufacturing process, yet none of the theoretical models include manufacturing errors, such as inconsistent segmentation of the magnetic pieces over the cylinder's surface or their imperfect position.
<br />
It is known that, for example, 2D segmentation causes creation of harmonics of the order of a multiple of the number of the segments. To deal with this common problem, the magnetic field over a sphere is analyzed using spherical harmonics. From this analysis, the placement of small compensating magnets is calculated to cancel the spherical harmonics and to improve magnet homogeneity. The field homogeneity may be also improved by correcting positions of the segments. However none of these methods is perfect. In our approach we propose to develop a method of shimming on a surface of a cylinder instead of a sphere, as traditionally used. We expect this approach will provide efficient shimming for ""short"" Halbach magnets.
<br />
In summary, we propose to develop a new design of a light, permanent magnet suitable for standard and ""gradient free"" MRI, co-developed by the applicant. As ""gradient free"" MRI does not require gradients of the magnetic field and associated amplifiers, it is feasible to produce inexpensive, light and silent MRI system for many new imaging applications.
<br />
<br />