Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Manitoba

$25,000.00

Development of a non-invasive Hand Artery Occlusion Detection using PPG signals

EF 2016-17

Résumé
Radial artery access is quickly becoming the state of the art in catheterization procedures, offering manyadvantages over the more traditional femoral access. Still, radial access poses new risks that must beconsidered when making the decision. One such risk is damage to the hand because of insufficient bloodsupply during the procedure, or from an overly tight compressive bandage following the procedure, which mayresult in anything from pain over several days to a permanent damage to function.The industrial partner of this project, Koven Technology Canada Inc. is interested in leveraging its corecompetencies in vascular diagnosis and new product commercialization to bring an innovative vasculardiagnostic product to market. The aim of this project is to investigate the feasibility of using thephoto-plethysmograph (PPG) signals collected at the tip of two fingers (i.e. thumb and little finger) recordedsimultaneously for detection of any occlusion of the hand arteries; the PPG signals are recorded in twoconditions: 1) when the radial artery is compressed physically for a temporary occlusion, and 2) when the ulnarartery is compressed for a temporary occlusion. The recording device is basically similar to any PPG/bloodpressure measuring device. Some pilot data will be collected by the PI and the industrial partner; the main partof the project will be dedicated to signal processing and development of an algorithm that can reliably andaccurately detect and quantify the arteries partial and full blockage in real time.Upon successful results of this project, development of a customized device prototype will be a futurecollaborative project; that will help Koven Technology Canada to reach its goal of developing and introducinga new vascular diagnostic product for to market.
Programme
Engage Grants Program
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
497291-2016
Name nom
KazemMoussavi, Zahra
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2514
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Digital signal processing
Research subject fr
Traitement des signaux numériques
Partie
1
Nb partie
1
Application title
Development of a non-invasive Hand Artery Occlusion Detection using PPG signals
Keyword
NSERC
Application summary
Radial artery access is quickly becoming the state of the art in catheterization procedures, offering manyadvantages over the more traditional femoral access. Still, radial access poses new risks that must beconsidered when making the decision. One such risk is damage to the hand because of insufficient bloodsupply during the procedure, or from an overly tight compressive bandage following the procedure, which mayresult in anything from pain over several days to a permanent damage to function.The industrial partner of this project, Koven Technology Canada Inc. is interested in leveraging its corecompetencies in vascular diagnosis and new product commercialization to bring an innovative vasculardiagnostic product to market. The aim of this project is to investigate the feasibility of using thephoto-plethysmograph (PPG) signals collected at the tip of two fingers (i.e. thumb and little finger) recordedsimultaneously for detection of any occlusion of the hand arteries; the PPG signals are recorded in twoconditions: 1) when the radial artery is compressed physically for a temporary occlusion, and 2) when the ulnarartery is compressed for a temporary occlusion. The recording device is basically similar to any PPG/bloodpressure measuring device. Some pilot data will be collected by the PI and the industrial partner; the main partof the project will be dedicated to signal processing and development of an algorithm that can reliably andaccurately detect and quantify the arteries partial and full blockage in real time.Upon successful results of this project, development of a customized device prototype will be a futurecollaborative project; that will help Koven Technology Canada to reach its goal of developing and introducinga new vascular diagnostic product for to market.