Grant: Engage Grants Program
Ryerson University
$25,000.00
Validating the Performance of Closed-Cell Spray-Applied Polyurethane Foam Insulation Applied to the Interior of Solid Brick Masonry Walls to Achieve Super-Insulated Levels
EF 2012-13
Résumé
Spray-applied (2lb closed cell) polyurethane foam insulation is rapidly becoming the insulation of choice for
single-family dwelling retrofit projects due to its high thermal resistance and excellent air-tightness
characteristics relative to other residential insulation options. However, little research and quantifiable data has
been published on the altering effects spray foam insulation has on the combined heat and moisture
performance of the building envelope when applied on the interior during retrofits to solid load-bearing
masonry walls, specifically in super-insulated thicknesses. As such, designers, home owners and building
officials support the product with little known of its long term performance.
The overall goal of this project is to quantify the combined heat and moisture performance of spray foam
insulation applied in super-insulated levels to the interior of solid brick masonry exterior walls. To achieve
this goal, a field study will be performed to acquire the necessary data. A simulation study will follow
allowing analysis of various spray foam installation permutations advantageous to the industry partner. The
case study research house employs super-insulated levels of spray foam insulation. An on-site weather station
will provide data to generate a localized weather file utilized in the simulation program in order to calibrate the
simulation model and produce accurate results for other simulated wall assemblies.
The specific output of this research will be measured and simulated data representing an understanding of the
combined heat and moisture performance of these wall assemblies. Using this knowledge, designers and
manufacturer's can improve building envelope design to be both energy efficient and durable.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
435118-2012
Name nom
Richman, Russell
Department département
Architectural Science
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Validating the Performance of Closed-Cell Spray-Applied Polyurethane Foam Insulation Applied to the Interior of Solid Brick Masonry Walls to Achieve Super-Insulated Levels
Keyword
NSERC
Application summary
Spray-applied (2lb closed cell) polyurethane foam insulation is rapidly becoming the insulation of choice for
single-family dwelling retrofit projects due to its high thermal resistance and excellent air-tightness
characteristics relative to other residential insulation options. However, little research and quantifiable data has
been published on the altering effects spray foam insulation has on the combined heat and moisture
performance of the building envelope when applied on the interior during retrofits to solid load-bearing
masonry walls, specifically in super-insulated thicknesses. As such, designers, home owners and building
officials support the product with little known of its long term performance.
The overall goal of this project is to quantify the combined heat and moisture performance of spray foam
insulation applied in super-insulated levels to the interior of solid brick masonry exterior walls. To achieve
this goal, a field study will be performed to acquire the necessary data. A simulation study will follow
allowing analysis of various spray foam installation permutations advantageous to the industry partner. The
case study research house employs super-insulated levels of spray foam insulation. An on-site weather station
will provide data to generate a localized weather file utilized in the simulation program in order to calibrate the
simulation model and produce accurate results for other simulated wall assemblies.
The specific output of this research will be measured and simulated data representing an understanding of the
combined heat and moisture performance of these wall assemblies. Using this knowledge, designers and
manufacturer's can improve building envelope design to be both energy efficient and durable.