Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

Carleton University

$25,000.00

Improvement of real-time phasor measurement unit model in hypersim

EF 2016-17

Résumé
OPAL-RT Technologies Inc. is currently receiving increasing demand from its customers all over the world requesting accurate phasor measurement unit (PMU) models on its real-time simulation hardware/software platform Hypersim. This situation is due to the extensive applications of the wide-area monitoring and control (WAMC) technology in recent smart grid development. WAMC is typically utilized to suppress inter-area oscillations in the power systems. Recently, it is also applied to high-voltage direct current (HVDC) systems and wind power generation Hypersim is a widely used real-time digital simulator capable of analyzing very large-scale power systems with more than 2000 three-phase buses. However, standard PMU model is still not included in the present version of Hypersim. There are several issues when PMU is modeled and simulated for either dynamic analysis or real-time simulation using Hypersim. First, Hypersim is mainly designed to simulate power systems. Therefore, it provides a large number of power blocks. However, digital signal processing blocks commonly used in PMU modeling are very limited in Hypersim. Second, different blocks in a PMU may operate at different rates. It is necessary to develop rate transition block to transfer data from the output of a blockoperating at one rate to the input of a block operating at a different rate. This is a challenging task in both PMU modeling and PMU testing since Hypersim has special requirements on the simulation step size. Third, the group delay caused by PMU filters must be compensated carefully in order to increase phasor estimation accuracy and reduce latency of output. The phasor estimation error may make the power control system unstable, and a high latency output is obviously harmful to the real-time testing. In this project, the detailed PMU model considering filter group delay compensation and operation rate conversion will be developed in Hypersim at first. Then an accuracy testing procedure for actual PMU devices in Hypersim will be given. After that, a benchmark WAMC system equipped with the developed PMU model
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
494395-2016
Name nom
Wang, Xiaoyu
Department département
Electronics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
1
Nb partie
1
Application title
Improvement of real-time phasor measurement unit model in hypersim
Keyword
NSERC
Application summary
OPAL-RT Technologies Inc. is currently receiving increasing demand from its customers all over the world requesting accurate phasor measurement unit (PMU) models on its real-time simulation hardware/software platform Hypersim. This situation is due to the extensive applications of the wide-area monitoring and control (WAMC) technology in recent smart grid development. WAMC is typically utilized to suppress inter-area oscillations in the power systems. Recently, it is also applied to high-voltage direct current (HVDC) systems and wind power generation Hypersim is a widely used real-time digital simulator capable of analyzing very large-scale power systems with more than 2000 three-phase buses. However, standard PMU model is still not included in the present version of Hypersim. There are several issues when PMU is modeled and simulated for either dynamic analysis or real-time simulation using Hypersim. First, Hypersim is mainly designed to simulate power systems. Therefore, it provides a large number of power blocks. However, digital signal processing blocks commonly used in PMU modeling are very limited in Hypersim. Second, different blocks in a PMU may operate at different rates. It is necessary to develop rate transition block to transfer data from the output of a blockoperating at one rate to the input of a block operating at a different rate. This is a challenging task in both PMU modeling and PMU testing since Hypersim has special requirements on the simulation step size. Third, the group delay caused by PMU filters must be compensated carefully in order to increase phasor estimation accuracy and reduce latency of output. The phasor estimation error may make the power control system unstable, and a high latency output is obviously harmful to the real-time testing. In this project, the detailed PMU model considering filter group delay compensation and operation rate conversion will be developed in Hypersim at first. Then an accuracy testing procedure for actual PMU devices in Hypersim will be given. After that, a benchmark WAMC system equipped with the developed PMU model