Grant: Collaborative Research and Development Grants
University of British Columbia
$19,000.00
Adapting membrane system operation and cleaning to varying raw water quality
EF 2016-17
Résumé
Membrane technologies are commonly used for water treatment applications throughout Canada and Internationally. The relatively rapid adoption of this novel technology over the past decade is largely due to its ability to produce high quality drinking water. During treatment, material that is retained at/in the membrane must be removed to prevent an excessive increase in the resistance to the permeating water. Hydraulic cleaning is typically used to remove most of the retained material (i.e. foulants). However, some of the foulants can only be removed chemically. Although effective at removing residual foulants, it is becoming increasingly evident that the use of chemical agents for membrane cleaning can negatively impact membrane performance. Over time, as a result of the impact of multiple chemical cleaning events, the membrane material is considered to have 'aged' beyond a trigger point and must be replaced. Coagulation-flocculation is commonly used prior to membrane filtration to improve the removal of contaminants in membrane systems, particularly components of dissolved organic matter that contribute to fouling. Because coagulation/flocculation affects the raw water matrix, it is also expected to impact the retention and accumulation of material by the membrane, and therefore chemical cleaning requirements as well as membrane ageing. Variations in source water quality are also expected to affect the performance of coagulation-flocculation and membrane systems and therefore chemical cleaning requirements. However, to-date, limited knowledge exists with respect to the effect of raw water quality and coagulation/flocculation practices on chemical cleaning requirements. The specific objectives of this study are to develop coagulation/flocculation protocols targeted specifically at the treatment of raw waters with highly variable characteristics, with the aim of identifying conditions that minimizing chemical cleaning requirements while maintaining water quality targets (concentration of organics, DBP precursor reduction).
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
485558-2015
Name nom
Bérubé, Pierre
Department département
Civil Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2015
Award amount
19000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
1500
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Environmental engineering
Research subject fr
Génie de l'environnement
Partie
2
Nb partie
2
Application title
Adapting membrane system operation and cleaning to varying raw water quality
Keyword
NSERC
Application summary
Membrane technologies are commonly used for water treatment applications throughout Canada and Internationally. The relatively rapid adoption of this novel technology over the past decade is largely due to its ability to produce high quality drinking water. During treatment, material that is retained at/in the membrane must be removed to prevent an excessive increase in the resistance to the permeating water. Hydraulic cleaning is typically used to remove most of the retained material (i.e. foulants). However, some of the foulants can only be removed chemically. Although effective at removing residual foulants, it is becoming increasingly evident that the use of chemical agents for membrane cleaning can negatively impact membrane performance. Over time, as a result of the impact of multiple chemical cleaning events, the membrane material is considered to have 'aged' beyond a trigger point and must be replaced. Coagulation-flocculation is commonly used prior to membrane filtration to improve the removal of contaminants in membrane systems, particularly components of dissolved organic matter that contribute to fouling. Because coagulation/flocculation affects the raw water matrix, it is also expected to impact the retention and accumulation of material by the membrane, and therefore chemical cleaning requirements as well as membrane ageing. Variations in source water quality are also expected to affect the performance of coagulation-flocculation and membrane systems and therefore chemical cleaning requirements. However, to-date, limited knowledge exists with respect to the effect of raw water quality and coagulation/flocculation practices on chemical cleaning requirements. The specific objectives of this study are to develop coagulation/flocculation protocols targeted specifically at the treatment of raw waters with highly variable characteristics, with the aim of identifying conditions that minimizing chemical cleaning requirements while maintaining water quality targets (concentration of organics, DBP precursor reduction).